4-10
4.7 X-cutter
4.7.1 Reassembling the Tape Sensor Unit
1. Fasten the leaf switch F assy to the tape sensor holder with the leaf switch screw.
2. Attach the tape sensor lever to the tape sensor holder.
3. Attach the tape sensor holder to the X-cutter unit with the sensor holder screw.
X-cutter unit
Leaf switch F assy
Leaf switch screw
Sensor holder screw
Tape sensor lever
Tape sensor holder
Fig. 4.7-1 Reassembling the Tape Sensor Unit
4.7.2 Installing the X-cutter Unit
Install the X-cutter unit into the chassis unit from above. Fasten it in position with the
two X-cutter screws.
X-cutter unit
X-cutter screws
Fig. 4.7-2 Installing the X-cutter Unit