2-94
Confidential
■
All one color
<User Check>
- Clean the corona wire of all four colors on the drum unit.
- Replace the drum unit with a new one.
Step
Cause
Remedy
1
Dirt on the electrodes of the
main body and the drum unit
Clean the electrodes of the main body and
the drum unit.
(Refer to
.)
2
Dirt on the electrodes of the
main body and the toner
cartridge
Clean the electrodes of the main body and
the toner cartridge.
(Refer to
.)
3
Dirt on the electrodes of the
main body and the belt unit
Clean the electrodes of the main body and
the belt unit.
(Refer to
.)
4
Laser unit flat cable failure
Replace the laser unit flat cable.
5
Dirt on the electrodes of the
high-voltage power supply
PCB
Clean the electrodes of the high-voltage
power supply PCB.
6
High-voltage power supply
PCB failure
Replace the high-voltage power supply PCB
ASSY.
7
Laser unit failure
Replace the laser unit.
8
Main PCB failure
Replace the main PCB ASSY.