Error status #2 Error code appears on the display when the power is turned on.
Probable causes
Check/ repair/ adjust
Parts to be replaced
1. If error E015 or E016 is displayed,
there is a poor connection of the
STOP switch.
a.
Check that the STOP switch is not stuck
down.
b. Check if there is a harness short-circuit.
c.
Check that connector P9 (HEAD
-SW) is
inserted into the main P.C. board.
STOP switch
2. If error E025, E035 or E045 is
displayed, the foot switch is still
depressed.
a. Check if the foot switch is still depressed.
b. Check if there is a short-circuit in the harness.
c.
Check if connector P12 (PEDAL) is connected
to the motor PCB.
d.
Reset the depression stroke for the foot switch
while referring to “
7-21. Standard setting for
depression stroke (foot switch)”.
* For a 3-pedal foot switch, the connector for the
main PCB will be P15 (PEDAL).
Treadle unit
3-pedal foot switch assembly
3. If "E055" is displayed, there is a
malfunction of the machine head
switch.
a. Check if the machine head switch is off.
b. Check if there is a broken wire in the harness.
c.
Check if connector P14 (HEAD
-SW) is
connected to the main PCB.
Switch assembly machine
head
4. If "E065" is displayed, one of the
keys on the operation panel is still
depressed.
a. Check that there is no incorrect sensitivity
when the surface of the panel sheet and the
keys are pressed.
b. Check that connector P3 (PANEL) is
connected to the motor PCB, and that
connector P1 (MAIN) is connected to the
panel PCB.
Operation panel assembly
LCD panel PCB assembly
Panel harness
5.
If “E131” is displayed, there is a
poor connection of the
synchronizer.
Check that connector P11
(RESOLVER) and P1
(MT
-ENC) is connected to the motor PCB, and
that connector P6 (MT
-ENC) is connected to the
main PCB.
6. If "E401" and "E410" is displayed,
there is a connection fault
between the main PCB, motor
PCB and the panel PCB.
a.
Check LD3 (green)
on the main PCB.
OK if illuminated.
b.
Check LD3 (green) on the motor PCB.
OK if illuminated.
c.
Check that connector P5 (MOTOR) is
connected to the main PCB, and that
connector P2 (MAIN) is connected to the
motor PCB.
d. Check that connector P3 (PANEL) is
connected to the motor PCB, and that
connector P4
(MAIN) is connected to the
panel PCB.
e. Check if there is a broken wire in the harness.
Main PCB assembly 800B
Motor PCB assembly 800B
LCD panel PCB assembly
Connection harness
Panel harness
(Continued on next page.)
Содержание HE-800B
Страница 7: ...v HE 800B Oil tank accessory 4732M 4731M 4730M ...
Страница 75: ...6 ASSEMBLY HE 800B 66 D E 0688D 0690D ...
Страница 126: ...9 ELECTRIC MECHANISM HE 800B 117 Power PCB Cutter PCB LCD panel PCB 0831D 0768D 0769D ...
Страница 133: ...9 ELECTRIC MECHANISM HE 800B 124 0851D ...
Страница 134: ...9 ELECTRIC MECHANISM HE 800B 125 0852D ...
Страница 135: ...9 ELECTRIC MECHANISM HE 800B 126 0853D ...
Страница 177: ...MEMO 168 HE 800B ...
Страница 178: ...SERVICE MANUAL 2014 Brother Industries Ltd All Rights Reserved HE 800B I3061003D 2014 03 D 1 ...