Broseley Desire SD1 Q7 Скачать руководство пользователя страница 6

200747_1TB 

 

Chimney Requirements 

 
Please note Broseley Fires do not provide flue pipes, closure plates or any other 
associated accessory. 
 

Top Flue Outlet Only 

 

The stove must be installed in accordance with current gas and buildings regulations 
BS5871: Part1. The appliance can be installed in any adequate area suitable for solid 
fuel fires and stoves. It can use a class 1, class 2 and pre-cast flue. 
 
For pre-cast flue installations it is ESSENTIAL that a sealed connection is made into 
the actual flue system (a void behind a closure plate is not permitted). Please refer to 
the codes of best practice for further advice on pre-cast flues. Before you install the 
stove, make sure the chimney flue outlet is correctly positioned to align with the flue 
outlet on the stove and that the chimney is in good condition. If not, a chimney liner 
must be installed or a suitable class II gas flue used. A draught is necessary to ensure 
the products of combustion are fully evacuated. 
 

Ideally it is recommended that the flue run is as straight as possible.  The flue 
must have a minimum vertical height of 3 metres to insure adequate draught. 
You can have a maximum of four bends in the run, each bend must not exceed 
45° and an additional metre of vertical flue should be provided for each bend. 
Ideally you should have a minimum vertical section of 600mm before any bend 
immediately off the top of the appliance, however it is permitted to use a 45° 
bend straight off the appliance provided you have an adequate flue draft.  
 

Prior to installation, the installer should insure that the flue is free from obstruction and 
any dampers must be fixed in a permanently open position. Ensure the chimney is not 
closed and that it has been swept and subsequently smoke tested. 
 
Make sure that rain, birds or any foreign body cannot get into the chimney to cause 
damage or blockage. This problem can normally be overcome by fitting an approved 
gas cowl. It is essential for the effective running of your stove that the chimney draws 
properly to allow the products of combustion to escape.

 

 

VENTILATION (GB ONLY) 

The gas stove is rated at less than 7kw and therefore does not normally require 
additional ventilation in the room (BS5871 

– part II).

 

 

Flue Spigot Connection 

Attach the supplied spigot to the top of the stove using the three M6x40 bolts and 
washers provided.  
 
 
 
 

 

 

Содержание Desire SD1 Q7

Страница 1: ...nventional Flue Natural Gas Stove Top Flue Outlet Only PLEASE LEAVE THESE INSTRUCTIONS WITH THE END USER Chimney closure plates are not supplied Please note gas installations MUST only be carried out...

Страница 2: ...Installation 9 Fitting the Decorative Log Retainer 10 Connecting the TTB Sensor 10 Positioning the logs 11 Assembling the door handle 20 Gas Connection Pressure Testing 20 Spillage Testing 21 Maintena...

Страница 3: ...nstaller That way you will have a clearer picture of what is involved It is required by law that the complete assembly installation and commissioning of gas stoves is carried out by a professionally q...

Страница 4: ...inal Output 4 7kW NOx 130 mg kWh GCV Please note this product is designed to only use natural gas G20 Dimensions Ignite CD1 Q7 WEIGHT 75 Kg Hereford CD2 Q7 WEIGHT 68 Kg Desire SD1 Q7 WEIGHT 71 Kg All...

Страница 5: ...minimum clearances are maintained irrespective of the materials used in the construction of the opening This has been tested and approved to allow adequate air flow and access to the controls as well...

Страница 6: ...imum vertical height of 3 metres to insure adequate draught You can have a maximum of four bends in the run each bend must not exceed 45 and an additional metre of vertical flue should be provided for...

Страница 7: ...crewdriver when fitting replacing the gas burner 1 Remove the stove body from its packaging and stand it in position 2 Open the main door 3 Insert the burner end with the control knob first followed b...

Страница 8: ...47_1TB 8 Assembly Burner Installation 6 Next place the 2 x ceramic rods into the slots located in the bracket above the burner as pictured 7 Next fit the mica boards as detailed in the next section Pa...

Страница 9: ...een the front of the stove and the rear mica Next rest the top mica board onto Finally fit the reaming side mica the side board this board will board and allow the top board to need supporting whilst...

Страница 10: ...he TTB sensor will be soldered to the cable and already mounted onto the bracket pictured left Attach the bracket to rear panel of the stove by inserting the keyhole cut outs over the existing screw h...

Страница 11: ...o be placed other than in accordance with these instructions will result in a charge being made following any service callout Replacement ceramics are available from your dealer We recommend lighting...

Страница 12: ...note you should have a single peg pointing upwards at the back 3 Do the same for the right hand side again you should have a single peg pointing upwards at the back Please note this lug simply rests...

Страница 13: ...rear log into position as shown below Position the rear log as shown with the thinner end to the right and the three holes facing you This log locates onto the pegs at the back as established in steps...

Страница 14: ...00747_1TB 14 Assembly Positioning the Logs 5 Position the central log as shown This log has a peg which locates into the central hole in the rear log After step 5 your log layout should look like this...

Страница 15: ...200747_1TB 15 Assembly Positioning the Logs 6 Position the next log as shown so that it locates onto the peg of the central log After step 6 your log layout should look like this...

Страница 16: ...200747_1TB 16 Assembly Positioning the Logs 7 The next ceramic locates into the right hole in the rear ceramic as shown After step 7 your log layout should look like this...

Страница 17: ..._1TB 17 Assembly Positioning the Logs 8 This ceramic locates into the left most hole in the rear ceramic You should have a peg pointing up at the front now After step 8 your log layout should look lik...

Страница 18: ...200747_1TB 18 Assembly Positioning the Logs 9 Position the small front log onto the last remaining peg as shown After step 9 your log layout should look like this...

Страница 19: ...s 10 Finally position the far left and far right logs as shown in the final ceramic layout below These logs do not have location points and simply rest up against the side vermiculite as pictured The...

Страница 20: ...ires an 8mm diameter semi rigid pipe not more than 1 meter in length This connection is a compression fitting sealant should never be used as this can potentially cause a blockage Pressure Testing Alw...

Страница 21: ...sensing spillage monitoring system in the form of an oxygen depletion sensing pilot This is designed to shut down the fire within a safe period if there is an excessive build up of products of combus...

Страница 22: ...Left hand side is not compressed SD1 AND CD1 MODELS ONLY Ensure that the stove is cold before proceeding Remove the door by lifting the door off the hinges Loosen the Hinge Locking nut inside the sto...

Страница 23: ...r a click Repeat until the pilot lights 3 Keep knob depressed at this point for 15 20 seconds 4 Upon releasing turn the knob Anti clockwise to select the low flame setting Turning the control further...

Страница 24: ...odour this is the paint curing and is completely normal Most high temperature paints operate in the same way They use a resin which dries at room temperature and a silicon resin which cures at high t...

Страница 25: ...ple and TTB to valve shown on page 9 is not loose You should not be able to move the interrupter by hand Any break in the following circuit will cause the pilot not to stay alight as the electrical ch...

Страница 26: ...ure that both ends of the TTB connection cable are firmly connected and not damaged If no damage look at tightening the thermocouple connection to the splitter see page 9 You will need an 8mm spanner...

Страница 27: ..._____Is the draught excessive __________ Is there any permanent ventilation in the room ____________________ Has the room double glazing ______________ Is the aeration of the pilot correct __________...

Страница 28: ...thin the guarantee period The guarantee is void if The appliance is not installed and operated in accordance with our instructions or Repairs or modifications have been carried out by the purchaser or...

Страница 29: ...ered Installer Full details are provided in this manual Broseley Fires Ltd First Floor Unit B Knights Court Archers Way Battlefield Enterprise Park Shrewsbury Shropshire SY1 3GA Product Fiche Manufact...

Отзывы: