QmB Series IP40, IP65, IP65XP
Section 2 Installation
2-2
Installation and Operation Manual
X-CM-QmB-eng
Part Number: 541B029AHG
June, 2008
2-4 Return Shipment
Prior to returning any instrument to the factory, contact your nearest Brooks
agent or a Brooks location listed below for a Return Materials Authorization
Number (RMA#). Information describing the reason for return, details on
the problems encountered, if any, as well as any requested work or
corrective action requests must be included with the returned device.
Brooks Instrument
407 W. Vine Street
P.O. Box 903
Hatfield, PA 19440 USA
Toll Free (888) 554-FLOW (3569)
Tel (215) 362-3700
Fax (215) 362-3745
E-mail: [email protected]
http://www.BrooksInstrument.com
Brooks Instrument
Brooks Instrument
Neonstraat 3
1-4-4 Kitasuna Koto-Ku
6718 WX Ede, Netherlands
Tokyo, 136-0073 Japan
P.O. Box 428
Tel 011-81-3-5633-7100
6710 BK Ede, Netherlands
Fax 011-81-3-5633-7101
Tel 31-318-549-300
Email: [email protected]
Fax 31-318-549-309
E-mail: [email protected]
A copy of Brooks Instrument Decontamination Statement, as well as a
Material Safety Data Sheet (MSDS) for the fluid(s) used in the instrument
must be included with the returned device. This documentation is required
before any Brooks personnel can begin processing the equipment. Copies
of the forms can be obtained from any Brooks Instrument agent or on-line
at www.brooksinstrument.com listed under the Service button
Any assembly or part must be returned with a Return Material
Authorization, which details the particulars about the device, the concerns
and any process situations that need to be noted. A copy of the RMA is
available on-line at www.brooksinstrument.com under the Support button
2-5 Transit Precautions
To safeguard against damage during transit, transport the instrument to the
installation site in the same container used for transportation from the
factory if circumstances permit.
2-6 Fluid Connections
General Mounting Practices
Use good piping practices to minimize transmitting any torque or bending
loads onto the process connections on the QUANTIM. Always verify there
are no leaks prior to starting QUANTIM on process fluid. The instrument is
delivered from the factory with a rigid surface mounting plate. For optimum
performance, this mounting plate should be used to mount QUANTIM to a
rigid surface. If panel mounting is required, the bottom of the instrument is
provided with two M4 and M6 (see dimensional drawings, Section A)
mounting holes to properly install the instrument on a rigid flat plate. Panel
mounting is not recommended for QUANTIM flow controllers with remote