QmB Series IP40, IP65, IP65XP
Section 5 Specifications
5-8
Installation and Operation Manual
X-CM-QmB-eng
Part Number: 541B029AHG
June, 2008
Certifications and Approvals
IP65XP Series Explosion-proof/ Flame-proof
United States and Canada- UL Recognized E73889, Vol. 1, Sect. 21.
Explosion-proof , Class I, Division 1, Groups C and D;
Dust Ignition-proof, Class II, Division 1 Groups E, F, and G;
Suitable for Class III, Division 1; T4
Per ANSI/UL 1203 and CSA 22.2 No. 30
Ex nC IIC T4
Per CSA E79-1
Class I, Zone 2, AEx nC IIC T4
Per UL 60079-1
Ambient Temperature: 0
o
C to 65
o
C
Enclosure: Type 4/ IP65
Europe - KEMA 05ATEX2052
II 2 G EEx d IIB T6
II 2 D T 85
o
C
Per EN 50014, EN 50018 and EN 50281-1-1
Ambient Temperature: 0
o
C to 65
o
C
Enclosure: IP65
Environmental effects
EMC effects:
The Brooks QUANTIM series meets the requirements of the EMC
directive 89/336EEC per EN 50081-2 and EN 61326-1. To meet
these specifications, the Brooks QUANTIM device must be directly
connected to a low impedance (less than 1 Ohm) earth ground.
Signals must use a standard twisted-pair, shielded instrument wire.
Pressure effects:
The Brooks QUANTIM series meets the requirements of the
Pressure Equipment Directive 97/23/EC. The unit falls into the
category "Sound Equipment Practice".