NOTE
To protect the port from damage, keep the cover on the port when not in use.
Perform the following steps to establish an Ethernet connection.
1.
Remove the shipping plug from the Ethernet port on the active management module.
2. Insert one end of an Ethernet cable into the Ethernet port.
3. Connect the other end to an Ethernet 10/100/1000 Base-T LAN.
You can access the device through a remote connection using the command line by way of Telnet or any of the management
tools, such as Brocade Network Advisor.
4. To complete any additional configuration procedures through a Telnet session, log in to the device by Telnet using the admin
login. The default password is
password
.
Customizing a host name
This procedure is optional.
While still in Telnet, you can change the host name of the device. The host name can be up to 30 characters long; it can include letters,
numbers, hyphens, and underscore characters; and must begin with a letter. The default host name is "sw0." The host name is displayed
at the system prompt.
1.
Log in to the device using an account that has the admin role.
2. Enter configure terminal to change to global configuration mode.
device# configure terminal
Entering configuration mode terminal
3. Enter switch-attributes followed by the RBridge ID and the host-name operand with the new name.
If you have changed the RBridge ID, be sure to use that ID.
device(config)# switch-attributes 1 host-name <host-name>
4. Record the new name for reference.
5. Enter exit while in global configuration mode to return to privileged EXEC node.
device(config)# exit
device#
6. To verify the new host name, you can run the show running-config command in EXEC mode.
device# show running-config
Customizing a chassis name
This procedure is optional.
While still in Telnet, you can change the chassis name. The chassis name can be up to 30 characters long; can include letters, numbers,
hyphens, and underscore characters; and must begin with a letter. The default chassis name is "VDX8770-#" where # is the number of
ports.
Brocade recommends that you customize the chassis name for each platform because some of the system logs refer to the platform by
its chassis name.
Initial Configuration
Brocade VDX 8770-4 Hardware Installation Guide
53-1002563-10
79
Содержание VDX 8770-4
Страница 1: ...HARDWARE INSTALLATION GUIDE Brocade VDX 8770 4 Hardware Installation Guide 53 1002563 10 1 June 2016...
Страница 8: ...Brocade VDX 8770 4 Hardware Installation Guide 8 53 1002563 10...
Страница 12: ...Preface Brocade VDX 8770 4 Hardware Installation Guide 12 53 1002563 10...
Страница 14: ...About This Document Brocade VDX 8770 4 Hardware Installation Guide 14 53 1002563 10...
Страница 26: ...Product Overview Brocade VDX 8770 4 Hardware Installation Guide 26 53 1002563 10...
Страница 70: ...Mounting the Device Brocade VDX 8770 4 Hardware Installation Guide 70 53 1002563 10...
Страница 124: ...Removal and Replacement Procedures Brocade VDX 8770 4 Hardware Installation Guide 124 53 1002563 10...
Страница 132: ...Brocade VDX 8770 Switch Technical Specifications Brocade VDX 8770 4 Hardware Installation Guide 132 53 1002563 10...