When you have assigned the IP and gateway addresses to management interface 1/1, you should also assign IP and gateway
addresses to management interface 1/2 if you have installed a second management module.
device(config)# interface Management 1/1
device(config-Management-1/1)# no ip address dhcp
device(config-Management-1/1)# ip address 10.24.85.81/20
device(config-Management-1/1)# ip gateway-address 10.24.80.1
NOTE
The ip gateway-address command will not be available on the device if the Layer 3 or Advanced Services license is
installed. In that case, use the following command sequence
switch(config)# rbridge-id 1
switch(config-rbridge-id 1)# ip route 0.0.0.0/0 <default-gateway>
If you are going to use an IPv6 address, enter the network information in semicolon-separated notation as prompted after the
ipv6 address operand. You should also disable DHCP.
device(config)# interface Management 1/1
device(config-Management-1/1)# no ip address dhcp
device(config-Management-1/1)# ipv6 address \
fd00:60:69bc:832:e61f:13ff:fe67:4b94/64
7.
Return to privileged EXEC mode by entering exit .
device(config)# exit
device#
8. To display the configuration, use the show running-config interface Management command.
device# show running-config interface Management 1/1
interface Management 1/1
no ip address dhcp
ip address 10.24.85.81/20
ip gateway-address 10.24.80.1
ipv6 address fd00:60:69bc:832:e61f:13ff:fe67:4b94/64
no ipv6 address autoconfig
!
Logging off the serial console port and disconnecting the serial cable
You can use the serial port to monitor error messages through the serial connection. If the serial port is no longer required, use the logout
command to log out of the serial console, remove the serial cable, and replace the protective plug in the serial port.
NOTE
To protect the port from damage, keep the cover on the port when not in use.
Establishing an Ethernet connection
After using a serial connection to configure the IP addresses for the device, you can connect the active management module to the local
area network (LAN).
NOTE
Connecting the management modules to a private network is recommended.
By establishing an Ethernet connection, you can complete the device configuration using a serial session, Telnet, or management
application, such as Brocade Network Advisor.
Initial Configuration
Brocade VDX 8770-4 Hardware Installation Guide
78
53-1002563-10
Содержание VDX 8770-4
Страница 1: ...HARDWARE INSTALLATION GUIDE Brocade VDX 8770 4 Hardware Installation Guide 53 1002563 10 1 June 2016...
Страница 8: ...Brocade VDX 8770 4 Hardware Installation Guide 8 53 1002563 10...
Страница 12: ...Preface Brocade VDX 8770 4 Hardware Installation Guide 12 53 1002563 10...
Страница 14: ...About This Document Brocade VDX 8770 4 Hardware Installation Guide 14 53 1002563 10...
Страница 26: ...Product Overview Brocade VDX 8770 4 Hardware Installation Guide 26 53 1002563 10...
Страница 70: ...Mounting the Device Brocade VDX 8770 4 Hardware Installation Guide 70 53 1002563 10...
Страница 124: ...Removal and Replacement Procedures Brocade VDX 8770 4 Hardware Installation Guide 124 53 1002563 10...
Страница 132: ...Brocade VDX 8770 Switch Technical Specifications Brocade VDX 8770 4 Hardware Installation Guide 132 53 1002563 10...