The sliders for the management module and switch fabric module and line card filler panels move toward the center of the
panel to release it.
2. Pull the filler panel out of the chassis using the release pins.
Replacing a filler panel
Do not leave a slot empty. This will adversely affect cooling of the chassis.
CAUTION
If you do not install a module or a power supply in a slot, you must keep the slot filler panel in place. If you run the chassis with
an uncovered slot, the system will overheat.
1.
Orient the filler panel.
The management module and switch fabric module and line card filler panels must be aligned with the slot guides.
The power supply filler panels simply fit into the slots.
2. Slide the filler panel into the slot until it is firmly seated.
The power supply panel may slide too far into the slot. Insert it only until the facing matches the facing of the other power
supplies or filler panels.
3. Move the sliders and release the release pins.
The release pins should retract completely.
Chassis ID card removal and replacement
Chassis ID (CID) cards cannot be removed or replaced by customers. If you experience a CID card failure, call Brocade Technical
Support.
When an error is detected, you can run the CID Recovery Tool to pinpoint the problem and, in some cases, fix it. If the problem is
determined to be in the critical seeprom portion of the card, no recovery is possible and you must contact Brocade Technical Support. If
however, the problem is in the non-critical seeprom, it is possible that you can use the recovery tool to fix the problem.
To run the CID Recovery Tool, enter the following command in Privileged EXEC mode.
sw0# cidrecov
If the problem is in the critical seeprom, the output indicates that you should call Brocade Technical Support. If the problem is in the non-
critical seeprom, the output describes the issue and the affected data and gives you several possible options for action.
For more detail concerning these options, refer to the "Using the Chassis ID (CID) Recovery Tool" chapter in the
Network OS Software
Troubleshooting Guide
and the "cidrecov" topic in the
Network OS Command Reference
.
TABLE 18 Options for the CID Recovery Tool
Condition
Recovery Option
One non-critical seeprom is corrupted.
Tool displays the CID to be recovered and prompts to continue or abort.
Both non-critical seeproms are corrupted.
Tool displays both CIDs to be recovered with default data and prompts to
continue or abort.
Neither non-critical seeprom is corrupted but there is a data mismatch.
Tool prompts for the CID to be recovered or to abort.
No corruption or mismatch is found.
Tool displays that there is nothing to be done and then exits on
acknowledgment.
Removal and Replacement Procedures
Brocade VDX 8770-4 Hardware Installation Guide
118
53-1002563-10
Содержание VDX 8770-4
Страница 1: ...HARDWARE INSTALLATION GUIDE Brocade VDX 8770 4 Hardware Installation Guide 53 1002563 10 1 June 2016...
Страница 8: ...Brocade VDX 8770 4 Hardware Installation Guide 8 53 1002563 10...
Страница 12: ...Preface Brocade VDX 8770 4 Hardware Installation Guide 12 53 1002563 10...
Страница 14: ...About This Document Brocade VDX 8770 4 Hardware Installation Guide 14 53 1002563 10...
Страница 26: ...Product Overview Brocade VDX 8770 4 Hardware Installation Guide 26 53 1002563 10...
Страница 70: ...Mounting the Device Brocade VDX 8770 4 Hardware Installation Guide 70 53 1002563 10...
Страница 124: ...Removal and Replacement Procedures Brocade VDX 8770 4 Hardware Installation Guide 124 53 1002563 10...
Страница 132: ...Brocade VDX 8770 Switch Technical Specifications Brocade VDX 8770 4 Hardware Installation Guide 132 53 1002563 10...