Memory Functions
These functions are shift functions in italics below the Proc Amp controls.
The ES-2200T stores all current settings, such as Proc-amp levels and system timing in its own non-volatile memory.
The memory is automatically updated once every three seconds. These settings are automatically recalled and
transferred to the resident TBC cards on power up, so that system timing and Proc-amp levels are not lost. System
timing information is stored separately for each resident card. Proc-amp levels are stored with respect to each TBC.
STORE
Holding in the VIDEO button for about a second activates this function. The memory store function causes the current
proc amp settings, including color balance and horizontal position, to be saved in non-volatile memory in the ES-
2200T. These settings may later be recalled using the recall function. When this function occurs, the front panel proc
amp LEDs flash.
RECALL
Holding in the BLACK button for about a second activates this function. The memory recall function is used to recall
settings previously stored using the store function. When this function occurs, the front panel proc amp LEDs flash for
one second.
PREVIOUS
Holding in the CHROMA button for approximately one second activates this function. The memory previous function
is used to return the proc amp settings to those present before a memory recall or unity function. When this function
occurs, the front panel proc amp LEDs flash for one second.
UNITY
Holding in the HUE button for approximately one second activates this function. The memory unity function returns all
proc amp and color balance settings to their factory-preset values. When this function occurs, the front panel proc amp
LEDs flash for one second.