Outlet Register Chart
Table 3.
System
Model
Airflow
Rate
(L/s)
A
Maximum
Ceiling
B
Typical
Floor
C
Minimum
Floor/Ceiling
D
Minimum
Floor/Ceiling
(Adaptive ZoningOnly)
SP5 & SP6 Heaters
External
SP630EN
850
15
23
7
3
SP630EN-XA
985
17
23
7
3
SP530EN
960
16
23
7
2
SP530EN-XA
965
17
23
7
2
SP623EN
715
12
12
5
2
SP623EN-XA
755
13
12
5
2
SP521EN
700
12
12
5
1.5
SP521EN-XA
740
13
12
5
1.5
SP5 & SP6 Heaters
Internal
SP635IN
1130
17
24
7
2.5
SP535IN
1160
17
24
7
2.5
SP630IN
1065
16
22
7
3
SP630IN-XA
1095
17
22
7
3
SP530IN
1080
17
24
7
2
SP530IN-XA
1140
17
24
7
2
SP623IN
765
12
13
5
2
SP623IN-XA
795
14
13
5
2
SP521IN
785
12
13
5
1.5
SP521IN-XA
830
14
13
5
1.5
SP615IN
695
12
13
5
2
SP4 Heaters
Universal
SP415UN
620
10
12
6
2
SP421UN
621
10
12
6
2
SP430UN
918
16
23
7
2
SP435UN
1004
17
23
7
3
Buffalo BX5
External
BX520EN (300mm)**
605
10
12
5
2
BX520EN (350mm)**
667
12
13
6
2
BX526EN (350mm)**
944
16
23
7
2
BX526EN (400mm)**
1011
17
23
7
3
** Model and basebox duct size
Note:
Airflow figures are based on a total static pressure of 125 Pa for 30 & 35 models and 50 Pa for other models.
Note:
Brivis Network 516 modules can only be used on heaters manufactured after 1 Mar 2010.
11. Thermostat Installation
All Brivis heating systems can be controlled by various Brivis Thermostats, each explained in detail below. A
Thermostat inside the house is wired to the control module in the heater. The Thermostat monitors the temperature
in the house, and switches the system ON and OFF in order to maintain a set temperature. So it must be
positioned correctly.
•
Install in the living area:
It is important that the Thermostat is placed in a position that will provide the most
accurate reading of the temperature, i.e. in the area most often used for family living.
•
Attach on an internal wall:
The temperature difference on an external wall can also affect it, so always
mount it on an internal wall. Keep the hole in the wall for the wiring as small as possible to prevent draught
from within the wall cavity affecting the temperature setting.
•
Get the height right:
The Thermostat should be approximately 1500mm above the floor level.
20
324702 CAAB024953 StarPro Installers Heat issue D.indd 23
17/05/16 8:41 AM