2. SP5 & SP6 Internal Model Guidelines
2.1 Heater Dimensions
Diagram 1.
SP6 & SP5 Internal
SP5 External
Dimension
[mm]
A
B
C
D
E
F
G
H
I
øSa
øRa
SP615IN
634
1021
395
594
440
440
15
513
224
300
300
SP623IN
634
1021
395
594
440
440
15
513
224
300
300
SP623IN-XA
634
1021
395
594
440
440
15
513
224
350
350
SP630IN
684
1070
547
643
491
490
15
563
253
350
350
SP630IN-XA
684
1070
547
643
491
490
15
563
253
400
400
SP635IN
684
1070
547
643
491
490
15
563
253
450
450
SP515IN
634
1021
395
594
440
440
15
513
224
300
300
SP521IN
634
1021
395
594
440
440
15
513
224
300
300
SP521IN-XA
634
1021
395
594
440
440
15
513
224
350
350
SP530IN
684
1070
547
643
491
490
15
563
253
350
350
SP530IN-XA
684
1070
547
643
491
490
15
563
253
400
400
SP535IN
684
1070
547
643
491
490
15
563
253
450
450
Dimension
[mm]
A
B
C
D
E
F
G
H
I
J
K
L
M
N
øSa
øRa
SP521EN
657
1046
416
15
104
520
211
-
620
-
210
-
224
480
300
300
SP521EN-XA
657
1046
416
15
104
520
-
230
-
580
-
231
224
480
350
350
SP530EN
707
1096
568
15
255
570
236
-
620
-
236
-
249
530
350
350
SP530EN-XA
707
1096
568
15
255
570
-
261
-
570
-
261
249
530
400
400
C
I
øSa
B
E
D
F
G
A
H
øRa
(SP6 MODELS ONLY)
A
B
C
D
E
F
G
I
K
M
H
J
L
øSa
øRa
N
A
B
C
D
E
F
G
I
K
M
H
J
L
øRa
øSa
N
B
C
E
Dimension
[mm]
A
B
C
D
E
F
G
H
I
øSa
øRa
SP615IN
634
1021
395
594
440
440
15
513
224
300
300
SP623IN
634
1021
395
594
440
440
15
513
224
300
300
SP623IN-XA
634
1021
395
594
440
440
15
513
224
350
350
SP630IN
684
1070
547
643
491
490
15
563
253
350
350
SP630IN-XA
684
1070
547
643
491
490
15
563
253
400
400
SP635IN
684
1070
547
643
491
490
15
563
253
450
450
SP521IN
634
1021
395
594
440
440
15
513
224
300
300
SP521IN-XA
634
1021
395
594
440
440
15
513
224
350
350
SP530IN
684
1070
547
643
491
490
15
563
253
350
350
SP530IN-XA
684
1070
547
643
491
490
15
563
253
400
400
SP535IN
684
1070
547
643
491
490
15
563
253
450
450
2.2 Service Clearances
Method 1 - In Ceiling & Under Floor
Method 2 - In Ceiling & Under Floor
Diagram 2.
Diagram 3.
750mm
Minimum
Fan
Cabinet
Heat
Exchanger
Cabinet
250 mm
Minimum
750mm
Minimum
Service Clearance
Heat
Exchanger
Cabinet
Fan Cabinet
Platform
Side View
Plan View
Fan
Cabinet
Heat
Exchanger
Cabinet
800 mm
Minimum
Platform
Service Clearance
Heat
Exchanger
Cabinet
Fan Cabinet
750mm
Minimum
Side View
Plan View
Method 3 - Lay Down Option -
Method 4 - Lay Down Option -
In Ceiling
Under Floor
Diagram 4.
Diagram 5.
Fire resistant board
(refer to AS5601)
700
750
300
(refer to AS5601)
service
clearance
(full length of heater)
Side View
Ground
750
200 (refer to AS5601)
Lowest part of floor structure
Concrete Base 50mm
service
clearance
(full length of heater)
700
Side View
4