• Mount the Brivis Networkers in their ideal locations and connect the wiring as shown in the diagram above.
• Determine which controller will be the Master and which one will be the Slave. There must be a Master and
Slave Brivis Networker for a dual Brivis Networker system to operate correctly. All Brivis Networkers come set as
Masters by default, which means only the Slave Brivis Networker needs to be configured.
Note:
A Master Brivis Networker can be identified by the word “Clock” beside key 5 (while the Brivis Networker is
in the off position). Refer to the Brivis Networker Advanced Programming manual for further information if required.
• Press key 5 on the proposed Slave Brivis Networker, and the screen will display the message “Clock setting
mode”. Ensure that the clock is flashing on the display before proceeding.
• Press and hold keys 2 & 4, until the screen displays the message “Installer parameter access”.
• After the message has finished, push the Mode key until the screen displays - n01 ID00:1 at the top (see
Diagram 22).
Diagram 22.
• Turn the rotary dial to change the parameter value displayed at the top right of the screen to the number
required for the Slave. (Master = 1, Slave = 2)
• Once this parameter value has been set, push the ON/OFF button to exit this installer set-up program.
This Brivis Networker will then become the Slave Brivis Networker, and the installer parameters will no longer be
accessible from this Brivis Networker. The Master Brivis Networker must then be used to access the installer parameters.
Note:
All Brivis Networkers come configured as Masters by default. Two Masters cannot be connected to one
system otherwise the system will not function properly. Also if both Brivis Networkers are set as Slaves, the Brivis
Networkers will lock out and will not be accessible.
Changing a Slave to a Master Brivis Networker
• Use this method if altering a current installation or if both Brivis Networkers have been set to Slave by mistake.
• Remove the Brivis Networker off the backing plate so that the controller is powered down.
• Press and hold keys 3 & 5, then place the Brivis Networker on the backing plate ensuring keys 3 & 5 are still
depressed.
• Continue holding keys 3 & 5 for five seconds after the control is placed on the backing plate.
• After holding keys 3 & 5 for five seconds, release the two keys. The screen should now scroll this message “Set
this Brivis Networker’s address!” If this message does not appear please repeat the resetting procedure.
• Now the parameter value can be set to “1” by rotating the dial, which will make this Brivis Networker a Master.
• Push the on/off button to exit.
Note:
For more information on the topics listed below please refer to the
Brivis Advanced Programming Manual
.
• Networker Installer Parameters
• Adaptive Zoning
• Controlling multiple appliances with one Networker
• Grouping multiple appliances into zones using one Networker
For the installation of Brivis ZonePlus control systems please refer to the Brivis ZonePlus Installer’s Manual.