11 INTERLOCK FUNCTIONS THAT ENSURE SAFE OPERATION
This machine features interlock functions to ensure the operators safety. Before
starting the machine, always make sure that these functions are valid. Your
machine tool supplier is not responsible for accidents that occur as a result of
the machine being operated without first validating these interlock functions.
Door Interlock
The door interlock function disables manual operation such as spindle
rotation and the cycle start of the automatic operation while the front
door/APC folding door is open.
The door interlock function protects the operator from operation errors
such as starting the spindle rotation while touching the spindle or a
workpiece, and dangers such as being caught by the table if the
operator has to carry out operation inside the machine.
Toolchanger Load Station/Checking Door Interlock
The ATC/Checking door interlock function disables the manual
operation of the ATC magazine and prevents automatic operation of
the machine whilst the door is open.
The door interlock function protects the operator by preventing him
from the danger of coming into contact with moving cutting tools or
being caught by the magazine whilst the magazine is rotating.
Note: Only the GX 480 DT/480 APC & 480 DT APC have toolchanger
load doors (left-side) and also only the GX 480 APC & 480 DT
APC have checking door (right-side).
Electrical Cabinet Door Interlock
When the electrical cabinet door interlock is positioned at “0”, power
can be turn ON while the electrical cabinet door is open. When the
electrical cabinet door interlock is positioned at “1”, power cannot be
turn ON while the electrical cabinet door is open.
The electrical cabinet door interlock function protects the operator from
receiving an electrical shock caused by touching a live device inside the
electrical cabinet by turning off the power while the electrical cabinet
door is open.