![BraunAbility EntervanII Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/braunability/entervanii/entervanii_owners-service-manual_2805236043.webp)
Page 41
Troubleshooting Diagnosis Chart
FUNCTION
SYMPTOM
POSSIBLE CAUSE
REMEDY
Check voltage. Replace if defective.
Replace if under 8.8 volts
Correct or replace
Correct
Tighten
Move transmitter within range
Replace receiver
Replace, connect or repair
Press switch to MANUAL position
Insert detent pin in release handle
(fully-rearward position)
Align, reroute, remove kinks, repair or
replace
Correct or replace
Correct or replace
Lubricate — * Apply Light Grease
Tighten, align or replace
Tighten or replace
Hold key in OPEN position for approxi-
mately two seconds to start operation
Connect, repair or replace
Adjust or replace
Replace fuse
Connect, repair or replace
Replace Time Delay
Realign, replace defective parts or
otherwise correct as needed
8.41 Vehicle battery
8.42 9 Volt battery low
8.43 Antenna deformed or damaged
8.44 Antenna contacting metal
8.45 Antenna loose in receiver
receptacle
8.46 Out of 35 foot maximum range
8.51 See 8.20
8.52 Defective receiver
9.11 Release cable missing, discon-
nected (turnbuckle connection at
motor, threaded mounting stud at
mounting bracket, release lever
connection), or otherwise
defective
9.12 Power still applied to actuator
(Kneel Actuator MANUAL/AUTO
switch not in MANUAL position)
9.21 Detent pin not inserted in release
handle (fully-rearward position)
9.22 Release cable out of adjustment,
out of alignment, routing obstruc-
tion, kinked, worn or otherwise
damaged
9.23 Manual release lever bent,
deformed or misaligned
9.24 Wear or damage to actuator shaft/
chain bearing slots
9.25 Lack of lubrication in actuator
shaft/chain bearing slots
9.26 Loose, misaligned or damaged
actuator shaft/chain bearing lock
collars
9.27 Loose or missing release cable
mounting bracket mounting bolts
10.11 See 1.00
10.12 Key Entry key not held in OPEN
position long enough (delay)
10.13 Key Entry Open microswitch
harness disconnected or
defective
10.14 Key Entry Open microswitch out
of adjustment or defective
10.15 Faulty fuse
10.16 Time Delay harness discon-
nected or defective
10.17 Time Delay defective
10.21 Misalignment, wear or damage
to slide lever, bushing spacers or
mounting bracket
10.22 See 10.14, 10.16 and 10.17
continued
continued
8.00
REMOTE
CONTROL
continued
continued
8.40
Poor
Reception
(Pulsating)
9.10
No
Operation
8.50
Signal Received
But No Operation
10.20
Faulty OPEN
Operation
9.00
KNEEL
ACTUATOR
MANUAL
RELEASE
10.00
KEY ENTRY
9.20
Faulty
Operation
10.10
No
OPEN
Operation
Troubleshooting