• Check that SCC is set to required temperature - decrease if
required. Temperature set point must be less than the room
temperature sensed by the SCC for the cooler to operate.
• Check that outlets/zones are open to all areas that require cooling.
• Check the return air grille is not obstructed.
• Check that the return air grille and filter are clean - clean if required.
• Check that the SCC is set to COOL mode - press AC MODE button
to change to COOL mode if required.
• If operating in MANUAL mode check that HOME is selected on
SCC - press HOME/AWAY button if required.
• Check that doors and windows are closed.
• If it is accessible, check that power is turned on to the cooling unit.
• Check that the SCC is set to COOL mode - press AC MODE button
to change to COOL mode if required.
• Allow 10 to 15 minutes for the system to operate then check again.
• If the air is still not cool contact your installer or the cooling
unit manufacturer.
TROUBLESHOOTING
PROBLEM: House is not heating effectively
PROBLEM: There is airflow from the outlets but it is not cool
• If it is accessible, check that power is turned on to the heater.
• Check that the SCC is set to COOL mode - press AC MODE
button to change to COOL mode if required.
• Check that SCC is set to required temperature - decrease if
required. Temperature set point must be less than the room
temperature sensed by the SCC for the cooler and heater fan to
operate.
• Where zones have been installed, check that the required zones
are turned on.
• If there is still no airflow from the outlets, contact your installer, or
call Seeley International Service on 1800 650 644.
PROBLEM: No airflow from outlets
• This may be normal operation due to low air flow.
• When the outlet temperature drops below a pre-set value the
cooling unit turns off to stop the cooling freezing. The cooling
unit re-starts after the outlet tempertature has increased enough
and the compressor re-start delay timer has elapsed.
• Increasing the fan speed will reduce the rate of cycling.
PROBLEM: Cooling unit cycles on and off
REMEDY
CAUSE
REFRIGERATED COOLING