7
SEELEY INTERNATIONAL –
HOME OWNER’S MANUAL
MAINTENANCE
Draining water from your cooler at the
end of the summer season is not
required if your cooler is fitted with an
automatic drain valve system. However
it is a requirement to check the cooler,
it's operation, the pump, drain valve,
water level, solenoid and fan motor
after the first year and then every two
(2) years as routine maintenance.
If the bleed system is fitted then
maintenance should be conducted
before and after every summer season
as outlined below.
WARNING:
Seeley International
recommends that maintenance is
carried out by an authorised service
agent. Climbing onto the roof is
hazardous and could result in personal
injury or property damage. Failure to
have maintenance carried out may
affect your warranty coverage. The
following instructions are provided for
you to pass on to your service agent, if
required, to ensure that the correct
maintenance is carried out.
End of Season Maintenance
1
Turn off power to cooler.
2
Turn off water to cooler.
3
Remove the pad frame assemblies -
take care not to damage the pads.
4
Turn off power switch inside the
cooler.
5
Check and clean the lid water
channels.
6
If fitted, unclip and remove the bleed
system. Allow water to drain. Take
care not to lose the o-ring.
7
Thoroughly clean the tank and
pump filter, DO NOT replace the
bleed system.
8
Refit the pad frames.
Preseason Maintenance
1
Turn off power to the cooler.
2
Remove the pad frames.
3
Ensure power switch in cooler is off.
4
Gently wash the pads to remove any
dust build up during winter. If the
pads are in poor condition, replace
them.
5
If removed, replace bleed system
and ensure the o-ring is re-fitted.
6
Turn on power switch in cooler.
7
Turn on water and power supply, refit
pad frames and run the cooler.
CAUTION: DO NOT RUN COOLER
WITH PAD FRAMES REMOVED
EVAPORATIVE COOLING