background image

SN2004/IR, SN2024/IR 

Installation

8

 

6/29/12

 Bradley 

• 215-1071 Rev. J; ECN 12-00-011

Turn off water supplies to the unit before troubleshooting.

Troubleshooting  – Solenoid Valve

Problem

Cause

Solution

An individual 

operating 

station fails to 

shut off and 

drips.

Debris is 

trapped between 

the diaphragm 

and the valve 

seat.

Remove debris between diaphragm and the valve seat.

1. Remove the three #8 Phillips-head screws that hold the solenoid valve assembly together. Be careful not 

to lose the armature or spring.

2. Remove the diaphragm. Remove any particles that have been trapped between the diaphragm and the 

valve seat. Rinse off the diaphragm and inspect for damage. Make sure the center orifice and both small 

side orifices are open.

3. Reassemble in reverse order (do not overtighten the Phillips-head screws or the plastic valve body may 

crack). Tighten until the armature plate makes contact with the plastic body.

4. Reconnect the wiring.

An individual 

operating 

station fails to 

turn on.

A failed coil for 

the valve or 

loose electrical 

connection to 

the terminal.

Test the station to determine the cause.

1.  Disconnect the wires from the coil of an adjacent valve. Disconnect the wires from the problem valve and 

reconnect to the adjacent valve.

2.  Turn on electrical and water supplies to the unit. Pass your hand in front of the sensor of the problem 

station, and the adjacent station should turn on.  
If the adjacent station turns on and cycles normally, replace the coil on the problem valve.
If the adjacent valve fails to turn on, inspect the wires from the sensor cable and do the following:

• make sure there are no breaks and that the fully insulated disconnect terminals are firmly crimped in 

place;

• turn off the electrical and water supplies;
• reconnect to the adjacent valve and turn on the water supplies to the unit;
• pass your hand in front of the sensor. If the station still fails to turn on, replace the sensor.

1

2

3

4

5

6

7

8

9

8

10

Item Qty.

Part No.

Description

Repair Kits

S65-113

S07-067 

(Closed Body)

S07-067A

(Thru Body)

1

1

118-307

Valve Body, 1/4" Closed

-

X

-

1

1

118-307A

Valve Body, 1/4" Thru

-

-

X

2

1

269-983

Diaphragm

X

X

X

3

1

269-577

Armature

X

X

X

4

1

269-578

Spring

X

X

X

5

1

269-1729

Armature Housing

-

X

X

6

1

269-1730

Clamp, Armature Housing

-

X

X

7

1

269-579

Coil, Solenoid Valve

-

X

X

8

3

160-447

Screw, #8 x 5/8

-

X

X

9

1

125-165

O-Ring, #2-013

-

X

X

10

1

110-231

Compression Nut 1/4" Tube

-

-

-

Содержание Sentry SN2004/IR

Страница 1: ...e of Contents Cleaning Instructions 2 Supplies Required 3 Rough In Information 4 Installation Instructions 5 Optional Equipment Installation 7 Troubleshooting 8 Sommaire Instructions relatives au nett...

Страница 2: ...direction as the polish lines Special Situations for Material Fingerprints and Smears To remove fingerprints or smears use a high quality stainless steel cleaner and polish in accordance with the manu...

Страница 3: ...debris accumulation Electrical cut off switch to the unit This feature prevents accidental water delivery during regular maintenance and service Dimensions Sentry Semi Circular Washfountain mm Floor U...

Страница 4: ...Trap supplied by Installer Type H Centrally rising vent P Trap furnished with unit Top View Top View 1 2 Supply Nominal Copper Tube 1 2 Supply Through Wall Optional Nominal Copper Tube 1 1 2 NPT Drain...

Страница 5: ...t if necessary Mark the wall anchor locations 2 Connect Water Supply to Valve Assembly Red Tube to Aerator Green Tube to Aerator Black Tube to Aerator Yellow Tube to Aerator Hot Supply Inlet Cold Supp...

Страница 6: ...Locking Nut Loosen before adjusting Vernatherm TMV Check to make sure stop check valves are open before turning on water B Turn on water supply and check for leaks Activate each IR Sensor to purge ai...

Страница 7: ...nt Brackets for a 1 1 2 pipe in a similar manner to above Secure brackets in position using tie bar supports as shown C Using supplied screws secure base of shroud to the sprayhead cover D Connect bas...

Страница 8: ...cause 1 Disconnect the wires from the coil of an adjacent valve Disconnect the wires from the problem valve and reconnect to the adjacent valve 2 Turn on electrical and water supplies to the unit Pas...

Страница 9: ...counterclockwise to increase the temperature or clockwise to decrease the temperature Limited water flow Dirt and debris have built up in the valve or strainer 1 Check to make sure both hot and cold s...

Страница 10: ...sp ciales de mat riau Empreintes et taches Pour liminer les empreintes ou taches utiliser un nettoyant pour acier inoxydable de haute qualit et polir conform ment aux instructions du fabricant De nomb...

Страница 11: ...pe circuit lectrique sur l unit Cette fonction emp che toute distribution d eau accidentelle durant l entretien ou les r parations standard Dimensions Lavabo fontaine semi circulaire Sentry mm Unit au...

Страница 12: ...hon en P fourni par l installateur A ration montante centralement de type H siphon en P fourni avec l unit Vue de dessus Vue de dessus Alimentation de 1 2 po Tube de cuivre nominal Alimentation de 1 2...

Страница 13: ...tremp e S39 685 en option Robinetterie arr t non retour A Connecter l extr mit femelle 1 2 po NPT de la robinetterie arr t non retour aux conduites d alimentation Connecter les arriv es d eau chaude e...

Страница 14: ...uster Vernatherm TMV V rifier que la robinetterie arr t non retour est ouverte avant d ouvrir l eau B Ouvrir l alimentation en eau et v rifier la pr sence ventuelle de fuites Activer chaque d tecteur...

Страница 15: ...o comme ci dessus S curiser les supports en position l aide des supports de fer de liaison comme il l est indiqu C l aide des vis fournies s curiser la base de l enveloppe sur le couvercle du bec diff...

Страница 16: ...la cause 1 D connecter les fils de la bobine d un bouton poussoir adjacent D connecter les fils du bouton poussoir probl matique et reconnecter au bouton poussoir adjacent 2 Mettre en marche les alim...

Страница 17: ...s d une montre pour augmenter la temp rature ou dans le sens des aiguilles d une montre pour diminuer la temp rature D bit d eau limit Salet et d bris se sont accumul s dans le robinet ou la cr pine 1...

Страница 18: ...el material Marcas de dedos y embarraduras Para quitar las marcas de dedos y las embarraduras use un limpiador de alta calidad para acero inoxidable de acuerdo con las instrucciones de f brica Muchos...

Страница 19: ...ctrico a la unidad Esta caracter stica evita el suministro accidental de agua durante el servicio y mantenimiento normal Dimensiones Fuente de lavado semicircular Sentry mm Unidad de piso 29 pulg 737...

Страница 20: ...el instalador Tipo H Ventilaci n ascendente desde el centro el sif n en P viene con la unidad Vista superior Vista superior Tubo de suministro de 1 2 pulg Tubo de cobre nominal Tubo de suministro de...

Страница 21: ...o de agua al conjunto de la v lvula Tubo rojo hacia el aireador Tubo verde hacia el aireador Tubo negro hacia el aireador Tubo amarillo hacia el aireador Entrada de suministro caliente Entrada de sumi...

Страница 22: ...e antes de ajustar Vernatherm TMV Revise para asegurarse de que las v lvulas de retenci n y cierre est n abiertas antes de encender el suministro de agua B Encienda el suministro de agua y revise que...

Страница 23: ...milar a la anterior Fije los soportes en su posici n con soportes de traviesa como se muestra C Con los tornillos que se proporcionan fije la base del recubrimiento a la cubierta de la boquilla rociad...

Страница 24: ...s cables de la bobina de una v lvula adyacente Desconecte los cables de la v lvula con problemas y vuelva a conectarlos a la v lvula adyacente 2 Encienda el suministro de electricidad y agua hacia la...

Страница 25: ...aumentar la temperatura o en el sentido de las agujas del reloj para disminuir la temperatura Flujo de agua limitado La suciedad y los desechos se han acumulado en la v lvula o en el filtro 1 Verifiqu...

Отзывы: