24
Venting (Part II) continued-
TABLE 7
2” (5.1 cm) VENT PIPE LENGTHS FROM INSIDE WALL FOR LOW
GROUND CLEARANCE INSTALLATIONS
Terminating
# of
Elbows
Max straight
Length ft (m)
Min straight
Length ft (m)
(2) 90
°
Elbows with Vent Terminal
1
30
(9.1)
2
(.6)
(2) 90
°
Elbows with Vent Terminal
2
25
(7.6)
2
(.6)
(2) 90
°
Elbows with Vent Terminal
3
20
(6.1)
2
(.6)
(2) 90
°
Elbows with Vent Terminal
4
15
(4.6)
2
(.6)
TABLE 8
3” (7.6 cm) VENT CONNECTOR LENGTHS FROM INSIDE WALL FOR
LOW GROUND CLEARANCE INSTALLATIONS
Terminating (Reduce 3” to 2”)
(Reduce 7.6 cm to 5.1 cm)
#of
Elbows
Maximum
Length ft (m)
Minimum
Length ft (m)
(2) 90
°
Elbows with Vent Terminal
1
100 (
30.5)
10
(3.1)
(2) 90
°
Elbows with Vent Terminal
2
95
(29.0)
10
(3.1)
(2) 90
°
Elbows with Vent Terminal
3
90 (
27.4)
10
(3.1)
(2) 90
°
Elbows with Vent Terminal
4
85
(25.9)
10
(3.1)
(2) 90
°
Elbows with Vent Terminal
5
80
(24.4)
10
(3.1)
HIGH ALTITUDE INSTALLATIONS FOR ELEVATIONS OVER 2,500
FEET (610 m) ABOVE SEA LEVEL
The capacit y of t he induced draf t blow er declines w it h increasing alt it ude
due t o a reduct ion in t he air densit y. In order t o assure saf e and reliable
perf ormance of t he w at er heat er, cont act t he supplier f or high alt it ude kit .
Содержание Combi2 TTW C-DW2-TW50T10FBN
Страница 15: ...15 Venting Part I continued 4 VENT INSTALLATION 3 VENT INSTALLATION Figure 3...
Страница 34: ...34 Wiring Diagram Figure 10...
Страница 36: ...36 Lighting and Shutdown instructions...
Страница 48: ...48 NOTES...