Part II - Venting Specifications for:
40 Gallon (151.4 L)
50 Gallon (189.2 L)
60 Gallon (227.1 L)
This w at er heat er is a pow er vent ed appliance and is designed t o vent it s
product s of combust ion t hrough 2’’
(5.1 cm)
or 3’’
(7.6 cm)
diamet er vent
pipe t o t he out doors. The w at er heat er may be eit her vent ed horizont ally
t hrough t he w all or vert ically t hrough t he roof . Use a 3’’
(7.6 cm)
t o 2’’
(5.1 cm)
reducer t o connect t o t he vent out let w hen using 3’’
(7.6 cm)
vent pipe. Apply proper cement at joint locat ions. Table 5 list s t he
maximum vent lengt hs f or t his w at er heat er using 2’’
(5.1 cm)
vent pipe. If
possible, locat e t he w at er heat er so t hat t he vent ing lengt h and number of
elbow s are kept t o t he minimum dist ance necessary t o reach t he out side. If
t he inst allat ion requires vent ing lengt hs t hat exceed t he lengt hs list ed f or
2’’
(5.1 cm)
vent pipe in Table 5 t hen use 3’’
(7.6 cm)
vent pipe f or t he
vent connect or.
Table 6 list s t he vent ing dist ances allow ed w it h 3’’
(7.6 cm)
diamet er vent
pipe.
When venting with 3’’ (7.6 cm) vent pipe
, use a 3’’
(7.6 cm)
t o 2’’
(5.1 cm)
reducer t o exit t hrough t he building w all w it h 2’’ (5.1 cm) vent
pipe. Use t he 2’’
(5.1 cm)
vent t erminal supplied w it h t he w at er heat er t o
t erminat e on t he out side of t he building. If t he lengt h of t he 2’’
(5.1 cm)
needed t o go t hrough t he w all is great er t han 14’’
(35.6 cm)
, use 3’’
(7.6
cm)
vent pipe t o go t hrough t he w all and reduce t o 2’’
(5.1 cm)
vent pipe
immediat ely af t er exit ing t he out side w all. Ref er t o t he vent ing illust rat ions
on t he f ollow ing pages. Make sure t he vent pipe t erminal is at least 1’’
(2.5
cm)
aw ay f rom t he edge of t he w all.
TABLE 5
VENT CONNECTOR LENGTHS FOR 2’’ (5.1cm) DIAMETER VENT PIPE
Terminating
# of 90
°
Elbows
(excluding vent
terminal)
Max straight
Length
ft (m)
Min straight
Length
ft (m)
Through t he Wall
1
45
(13.7)
2
(.6)
Through t he Wall
2
40
(12.2)
2
(.6)
Through t he Wall
3
35
(10.7)
2
(.6)
Through t he Wall
4
30
(9.1)
2
(.6)
Through t he Roof
0
50
(15.2)
7
(2.1)
Through t he Roof
1
45
(13.7)
7
(2.1)
Through t he Roof
2
40
(12.2)
7
(2.1)
Through t he Roof
3
35
(10.7)
7
(2.1)
Through t he Roof
4
30
(9.2)
7
(2.1)