7
OP
HE
RA
22
A
23
24
The number of confirmation signals also indicates
the number of present and programmed entry
panels (1 signal for the main entry panel and 1
signal for each secondary entry panel).
4 -
Refit jumper SW1.
Programming receivers
1 -
Remove jumper SW2 from any entry panel.
2
- Simultaneously press the door-lock release
and auxiliary 2
buttons for at least 1 s (the video,
if present, will activate, to confirm that hte operation
has occurred).
3
- Briefly press the
button to establish contact
with the entry panel.
4 -
On the entry panel, press the call button the
receiver is to be associated with.
5 -
Repeat the operation from point 2 on for all
remaining receivers.
6 -
Refit jumper SW2 to exit programming.
WARNING. The programming procedure for the
VSE/301 selector, where fitted, must only be
performed once you have programmed which
calls from the entry panels are to be associated
with which receivers.
In installations with XA/300LR we recommend
you gather up the receiver’s ID (SN) codes,
applied on the outside of the housing, and enter
them in the tables that come with the XA/300LR,
MPP/300LR and IPC/300LR.
NOTE. Once the power supplier has been pro-
grammed using a PCS/300 or MPP/300LR unit, it
will no longer be possible to gain access to the
entry panel standard programming.
To restore default conditions, please refer to the
related chapter.
Return to default conditions from entry panel
1 -
Remove the SW1 jumper.
2 -
Close the earthed door open contact (
–,
).
A sound signal confirms that the operation has
occurred.
3 -
Replace the SW1 jumper
COLOUR VIDEO ENTRY PANEL HEVC/301
Video entry panel complete with colour CCD came-
ra and white-light LED for lighting the target area.
Its features and functions are similar to those of
entry panel HEV/301.
Technical features
• Power supply:
14÷18 V DC.
• Current demand:
- on stand-by with 14V DC max. 230 mA;
- operating with 14V DC max. 380 mA;
- with door-lock release activated, add 500 mA;
- for each HEP/306-HEP/312D, add 35 mA;
- for each XDV/300A connected, add 40 mA;
- for 64 receivers, add 64 mA.
• Secrecy of speech/privacy of video signal.
• Door-lock release command: pulse-type for sole-
noid lock at 12 V 1 A.
• Timed solenoid door-lock release: adjustable in
the range 1 to 15 s.
• Installation activation time: 60 s.
• Call duration time: 30 s.
• Bus output: power supply at 15 V DC for booster
and receivers video driver balanced type (Z =
100
Ω
).
• Aux 1 command output: 3.5 V DC at 1 mA (avai-
lable only with entry panel enabled, activation
time same as timed solenoid door-lock release).
• Aux 2 command output: 3.5 V DC at 1 mA (always
available in all entry panels, activation time same
as timed solenoid door-lock release).
• Entry panel activation output: 3.5 V DC at 1 mA
(enabled for entire duration of conversation).
• Working temperature range: -15 °C to +50 °C.
Camera technical features of HEV/301 entry panel
• Video signal system: CCIR (EIA).
• Sensor: 1/4” CCD.
• Horizontal frequency: 15,625 Hz (15,750 Hz EIA).
• Vertical frequency: 50 Hz (60 Hz EIA).
• Video output: 1 Vpp composite to 75
Ω
.
• Resolution: 380 lines.
• Minimum illumination: 5 lx.
• S/N ratio: 45 dB.
• Iris control: automatic electronic in the range 1/50
s 1/100,000 s.
• Lens: fixed-focus f 3.7 F 4.5.
Camera technical features of HEVC/301 entry panel
• Video signal system: PAL.
• Sensor: 1/4” CCD.
• Horizontal frequency: 15,625 Hz.
• Vertical frequency: 50 Hz.
• Video output: 1 Vpp composite to 75
Ω
.
• Resolution: 330 lines.
• Minimum illumination: 50 lx.
• S/N ratio: 46 dB.
• Iris control: automatic electronic.
• Lens: fixed-focus f 3.7 F 5 (pin-hole).
INSTALLATION
WARNING. It is recommended to install the
monitor in a dry place.
PHI embedding box
The embedding box can be installed in either
masonry or plasterboard walls at a height that is
suitable for the user (fig. 9-10-11).
Make sure the UP indication is facing the right way
indicated on the bottom of the embedding box.
- Dimensions: 130x114x53,5 mm.
Masonry wall installation
The embedding box should be installed flush with
the wall, and equipped with the provided protection
(fig. 12).
Installation on plasterboard walls
Press the box against the wall to get four reference
points where the holes with a 10 mm diameter will
be made (fig. 13).
Cut the plasterboard to obtain the hole where the
box will be inserted (fig. 14).
Remove the three tabs as shown in figure 15.
Insert the upper part A of the fastening clamps into
the box, leaving the lower part B free (fig. 16).
Place the embedding box into the hole and then
apply the lower part B (fig. 17).
Secure the box to the wall with the screws provided
(fig. 18).
If the wall is more than 2 cm thick, the two parts of
the fastening clamps will need to be separated,
positioning the lower part B as shown in figure 19.
OPHERA and OPHERA/B video handset
Remove the two covers as shown in fig. 20. Wire the
connections.
Fasten the appliance to the embedding box, using
the screws provided (fig. 21).
Insert the covers as shown in fig. 22.
Replace the covers
The appliance is equipped with 3 sets of exchan-
geable covers in different colours.
To replace, proceed as shown in fig. 20 and 22.
Video entry panel HEV/301-HEVC/301
The embedding box must be fitted flush with the
wall and at an height that ensure optimal camera
operation. Fit the spacer into embedding boxes to
avoid deformation (fig. 23).
WARNING. Connecting cables must be fed through
one of the knockout cable entry points, located at
the bottom of the embedding box (A in fig. 23).
Using the Allenkey s 2.5 supplied, unscrew the lock
screw and remove the front plate from the chassis
(fig. 24).
In order to fit additional buttons, follow the instruc-
tions supplied with each.
Remove the two plugs protecting the threaded
holes in the embedding box and secure the chas-
sis using the two screws supplied (fig. 25).
Perform the wiring. The name card can be removed
and filled in with the relevant information by remo-
ving the card clip followed by the actual card itself
(fig. 29).
NOTE.
Personalized name cards can be used up to
a maximum of 2 mm thick.
In order to fit the front plate, first insert the upper
part in the top moulding and then, using a Allenkey
s 2.5, tighten the lock screw (fig. 30).
DISPOSAL
Do not litter the environment with packing material:
make sure it is disposed of according to the regula-
tions in force in the country where the product is
used.
When the equipment reaches the end of its life
cycle, take measures to ensure it is not discarded in
the environment.
The equipment must be disposed of in compliance
with the regulations in force, recycling its compo-
nent parts wherever possible.
25