RANGE
Mobile bain-marie GN2/1 or 2GN1/1 (
y
ref. 872002
) - one thermostat.
Mobile bain-marie 1 GN2/1 + 1 GN1/1 or 3GN1/1 (
y
ref. 872003
) - one thermostat.
Mobile bain-marie with 2 GN1/1 tanks with hot steam cabinets and separate thermostat (
y
ref.872112
without lid or
ref.872212
with lid) or without hot steam cabinet
(ref.872012 - 872312)
with sepa-
rate thermostat.
Mobile bain-marie with 3 GN1/1 tanks with hot steam cabinets and separate thermostat (
y
ref.872113
without lid or
ref.872213
with lid) or without hot steam cabinet
(ref.872013 - 872313)
with sepa-
rate thermostat.
Capacity of each hot steam cabinet : 3 containers GN1/1 H100.
y
UTILISATION
The bain-marie and hot air steam cabinets are solely for maintaining temperature levels; they can-
y
not be used to cook or reheat food.
Current legislation requires the food to be loaded in bain-marie at a temperature above 63°C.
y
DESCRIPTIF TECHNIQUE
Models
LxPxH mm
Net weight
Max load
Voltage
Power
Amperage
IP
872002
870x680x900
40 kg
60 kg
230V single phase 50/60 Hz
1300 W
6 A
33
872003
1195x680x900
55 kg
90 kg
230V single phase 50/60 Hz
2100 W
9 A
33
872012
900x690x900
45 kg
60 kg
230V single phase 50/60 Hz
1400 W
6 A
33
872112
900x690x900
65 kg
100 kg
230V single phase 50/60 Hz
2000 W
9 A
33
872212
900x690x950
70kg
100 kg
230V single phase 50/60 Hz
2000 W
9 A
33
872013
1280x690x900
60 kg
90 kg
230V single phase 50/60 Hz
2100 W
9 A
33
872113
1280x690x900
95 kg
150 kg
230V single phase 50/60 Hz
3000 W
13 A
33
872213
1280x690x960
105 kg
150 kg
230V single phase 50/60 Hz
3000 W
13 A
33
872312
835x755x900
40 kg
60 kg
230V single phase 50/60 Hz
1300 W
6 A
33
872313
1215x755x900
55 kg
90 kg
230V single phase 50/60 Hz
2100 W
9 A
33
Each tank and hot steam cabinet is separately regulated by a thermostat from 0°C to 100°C.
ELECTRICAL CONNECTION
Insulated spiral cable including earth, pvc coated 1 mm2 section wire, in polyurethane cover.
y
230 V - single phase 50/60Hz.
y
Single phase 3-pin plug, 16 amps, (13 amps for UK), to be protected against variations in intensity.
y
The unit can not be connected without the single phase plug. In case of any changes, we will accept
y
no liability.
Ensure that the illuminated switch is in off position before turning power on or off.
y
EU stamped.
OPERATION
HOT STEAM CABINETS
Set the enclosure(s) in use to 80°C.
y
Allow to preheat for 30 mins.
y
Insert food that has already been heated.
y
ENGLISH