Bosch VideoJet 8004 Скачать руководство пользователя страница 7

VideoJet 8008 / VideoJet 8004

 | Installation and Operating Manual

EN 

| 7

Bosch Security Systems | 2006-07 | V1.5

Safety information

Safety information

2

Electric shock hazard

Never attempt to connect the unit to any power network other than the type 
for which it is intended.

Never open the housing.

If a fault occurs, disconnect the unit from the power supply and from all other 
units.

Install the unit only in dry, weather-protected locations.

If safe operation of the unit cannot be ensured, remove it from service and 
secure it to prevent unauthorized operation. Safe operation is no longer pos-
sible in the following cases:

– if there is visible damage to the unit or power cables,

– if the unit no longer operates correctly,

– if the unit has been exposed to rain or moisture,

– if foreign bodies have penetrated the unit,

– after long storage under adverse conditions, or 

– after exposure to extreme stress in transit.

In such cases, have the unit checked by Bosch Security Systems.

Содержание VideoJet 8004

Страница 1: ...VideoJet 8008 VideoJet 8004 ...

Страница 2: ...ed with all due care and all information contained in it has been thoroughly checked The description was complete and correct at the time of going to press Our products are constantly developed and upgraded as such the content of the manual is subject to change without notice Bosch Security Systems accepts no liability for losses that arise directly or indi rectly as a result of errors incompleten...

Страница 3: ... 9 System requirements for setup 9 Configuration requirements 10 Operational requirements 10 Overview of functions 11 Connections on the rear panel 14 Front panel 15 Chapter 4 Installation Installing in a switch cabinet 18 Connections 20 Power on Power off 24 Setup using a terminal program 25 Chapter 5 Configuration using a Web browser Connecting 29 Choosing the configuration mode 31 Unit overview...

Страница 4: ...ng options on the front panel 135 Chapter 7 Maintenance and upgrades Testing the network connection 139 Restart Reset 139 Repairs 140 Transfer and disposal 140 Chapter 8 Appendix Troubleshooting 141 LEDs 143 RS232 485 interface 144 RS232 interface audio versions only 145 Terminal block 146 Second terminal block audio versions only 147 Glossary 148 Technical data VideoJet 8008 150 Technical data Vi...

Страница 5: ...s Rele vant knowledge of network technology is required The manual describes the installation and operation of the unit Conventions In this manual the following symbols and notations are used to draw attention to special situations Caution This symbol indicates that failure to follow the safety instructions described may endanger persons and cause damage to the unit or other equipment It is associ...

Страница 6: ...er applications are not permitted In the event of questions concerning the use of the units which are not answered in this manual please contact your sales partner or Bosch Sicherheitssysteme GmbH Robert Koch Straße 100 85521 Ottobrunn Germany www bosch sicherheitssysteme de EU Directives The VideoJet 8008 and VideoJet 8004 network video servers comply with the requirements of EU Directives 89 336...

Страница 7: ...nstall the unit only in dry weather protected locations If safe operation of the unit cannot be ensured remove it from service and secure it to prevent unauthorized operation Safe operation is no longer pos sible in the following cases if there is visible damage to the unit or power cables if the unit no longer operates correctly if the unit has been exposed to rain or moisture if foreign bodies h...

Страница 8: ...stood the documentation for the other equipment connected to it such as cameras The documentation contains important safety instructions and information about permitted uses Perform only the installation and operation steps described in this manual Any other actions may lead to personal injury damage to property or damage to the equipment Maintenance and repair Never open the housing of a VideoJet...

Страница 9: ...tion in 19 inch racks Quick Installation Guide Product CD with the following content Quick Installation Guide Manual System Requirements document MPEG ActiveX control MPEG viewer DirectX control Microsoft Internet Explorer Microsoft Virtual Machine Adobe Acrobat Reader System requirements for setup Computer with Windows 2000 XP operating system access to a network and Microsoft Internet Explorer v...

Страница 10: ...oftware and controls from the product CD supplied see Components supplied page 9 Operational requirements Computer with Windows 2000 XP operating system access to a network and Microsoft Internet Explorer version 6 0 or higher or Computer with Windows 2000 XP operating system access to a network and receiver software such as VIDOS or MPEG 4 compatible hardware decoder from Bosch Security Systems f...

Страница 11: ...witch cabinet Mounting in a 19 inch rack using the mounting kit supplied is a quick and easy operation Receiver Compatible MPEG 4 enabled hardware decoders for example the VIP XD can be used as receivers Computers with decoding software such as VIDOS or computers with the Microsoft Internet Explorer Web browser can also be used as receivers Video encoding VideoJet 8008 and VideoJet 8004 use the MP...

Страница 12: ...xternal units such as pan or tilt heads for cameras or motorized zoom lenses control data is transmitted via the bidirectional serial interface This interface can also be used to transmit transparent data Configuration The units can be configured with a Web browser via the local network Intranet or via the Internet In the same way firmware updates and fast loading of device configurations are poss...

Страница 13: ...ia RS232 RS422 RS485 serial inter face Local long term recording on integrated hard drive Remote control for all internal functions with TCP IP Password protection to prevent unauthorized connection or configuration changes Ten alarm inputs for external sensors such as door contacts Built in video sensor for motion and tamper alarms Event controlled automatic connection for example at switch on an...

Страница 14: ...el 4 RS232 serial interface audio versions only 9 pin sub D socket m as additional serial interface 5 Eight video inputs Video 1 to Video 8 BNC sockets for connecting the video sources each with a switch for 75 Ohm terminating resistance 6 Ten alarm inputs IN1 to IN10 Push in terminal for connecting external signal sources or switches 7 RS232 485 serial interface RJ45 socket for transmitting contr...

Страница 15: ...sions 12 HDD LED flashes red during data transmission to and from the hard drive 13 Fail LED flashes red during hardware error defective fans 14 Display for displaying operating parameters 15 Menu Exit key for activating and deactivating the configuration menu 16 Set key for saving changes to the operating parameters for future function extensions 17 Arrow keys for navigation in the display menu F...

Страница 16: ...Installation and Operating Manual VideoJet 8008 VideoJet 8004 EN 16 Product description Bosch Security Systems 2006 07 V1 5 ...

Страница 17: ...F and the relative humidity must not exceed 80 non condensing The unit heats up during operation so you should ensure that there is ad equate ventilation and enough clearance between the unit and heat sen sitive objects or equipment Please ensure the following installation conditions Do not install the unit close to heaters or other heat sources Avoid locations exposed to direct sunlight Allow suf...

Страница 18: ...e unit heats up during operation so you should ensure that there is enough clearance between the unit and other heat sensitive equipment or objects When mounting additional units direct contact is permitted provided that the surface temperature of the adjacent units does not exceed 40 C 104 F Installing the unit On the left and right hand sides of the housing loosen the two screws on the front pan...

Страница 19: ...VideoJet 8008 VideoJet 8004 Installation and Operating Manual EN 19 Bosch Security Systems 2006 07 V1 5 Installation Installation overview ...

Страница 20: ... 4 6 8 are assigned If all eight inputs are assigned the VideoJet 8004 supports a maximum resolution of 2CIF at the full image rate Mixed assignment is also possible for example assign Video 1 to Video 4 2CIF and then only Video 5 and Video 7 4CIF each Connect the cameras or other video sources with a video cable 75 Ohm BNC plug to the BNC Video 1 to Video 8 sockets Set the 75 Ω sliding switch und...

Страница 21: ...tructions and information about permitted uses Note A video connection is necessary to transmit transparent data Network You can connect the unit to a 10 100 1000 Base T network using a standard UTP category 5 cable with RJ45 connectors Connect the unit to the network via the 10 100 1000 MBit Base T socket Alarm inputs VideoJet 8008 and VideoJet 8004 offer ten alarm inputs via an orange terminal b...

Страница 22: ... the same audio stream Selection is carried out using the software user interface The following specific audio ports are available Audio 1 to Audio 8 Socket input output mono line level Audio Out Socket output stereo line level AI Terminal connector input mono speaking level AO Terminal connector output mono speaking level Note If possible you should use the line ports of the intercom for transmit...

Страница 23: ... connecting external units such as lamps or alarm sirens You can operate these relay outputs manually while there is an active connection to the device The output can also be configured to automatically activate sirens or other alarm units in response to an alarm signal The relay outputs are also located on the orange terminal block Caution A maximum load of 30 V and 2 A may be applied to the rela...

Страница 24: ... voltage surges spikes or voltage drops Caution You should only connect the unit to the mains once all other connections have been made Plug the rubber connector of the power supply cable into the Power socket Connect the power supply cable to a fused mains socket The green Power LED on the front panel of the unit lights up As soon as the text VideoJet 8008 or VideoJet 8004 is displayed on the scr...

Страница 25: ...ory included with Microsoft Windows can be used as the terminal program Note Information on installing and using HyperTerminal can be found in the manuals or in the online help for MS Windows Disconnect the unit from the data network before working with the terminal program Connect the unit s RS232 485 RJ45 socket to a free serial interface on the computer Configuring the terminal Before the termi...

Страница 26: ...the display Enter one command at a time When you have entered a value such as an IP address check the charac ters you have entered before pressing the ENTER key to transfer the values to the unit Assigning an IP Address To use a VideoJet 8008 or VideoJet 8004 in your network you must assign it an IP address that is valid for your network The following default address is preset at the factory 192 1...

Страница 27: ...ogram dis plays the new IP address If necessary enter command s and a new subnet mask Note You must restart to activate the new IP address a new subnet mask or a gateway address Restart Briefly disconnect the power supply from the unit unplug the power supply cable and plug it in again after a few seconds Additional parameters You can use the terminal program to check other basic parameters and mo...

Страница 28: ...Installation and Operating Manual VideoJet 8008 VideoJet 8004 EN 28 Installation Bosch Security Systems 2006 07 V1 5 ...

Страница 29: ...oft Virtual Machine is installed and activated on your PC If necessary you can install the required software and controls from the product CD supplied see Components supplied page 9 Instructions for using the Web browser can be found in its online help System requirements Microsoft Internet Explorer version 6 0 or higher Monitor resolution 1024 768 pixels Network access Intranet or Internet Note A...

Страница 30: ...irectory of the CD in Windows Explorer and double click MPEGAx exe Follow the on screen instructions Establishing the connection To operate the unit in your network it must have a valid IP address for your network The following default address is preset at the factory 192 168 0 1 Start the Web browser Enter the unit s IP address as the URL The connection is established and after a short time you w...

Страница 31: ...hen you call up access protected areas Note The unit offers the option of limiting access across various authorization levels see pages 48 and 65 Enter the user name and associated password in the corresponding text fields Click OK If the password is entered correctly the Web browser displays the page that was called up Choosing the configuration mode There are two options for configuring the unit...

Страница 32: ...his mode Settings that affect the fundamental functioning of the unit such as firmware updates can only be made using the configuration menu Starting configuration Click the SETTINGS link in the upper section of the LIVEPAGE window The Web browser opens a new page containing the configuration menu see Configuration menu page 63 and the unit overview see Unit overview page 33 Note The screen displa...

Страница 33: ...will open Click in the text fields to enter values or use the other controls that are avail able such as buttons checkboxes or list fields Click the SETTINGS link at the top of the window to close the window without saving the changes made Making changes After making changes in a window click the Set button to send the new settings to the unit and to save them there Caution Save the changes made i...

Страница 34: ...b Selecting a profile You can configure the MPEG 4 data transmission in accordance with the oper ating environment for example network structure bandwidth data load For Dual Streaming compatible units each encoder can create two data streams at the same time with different compression settings such as for transmission and local saving Note The settings must be made individually for each camera inp...

Страница 35: ...onnections via two B channels resolution 352 288 240 pixels Profile 6 ISDN 1B For ISDN connections via one B channel resolution 352 288 240 pixels Profile 7 Modem For analog modem connections at 20 kBit s resolution 352 288 240 pixels Profile 8 GSM For GSM connections at 9 600 baud resolution 176 144 120 pixels Active profile for video 1 to Active profile for video 8 Here you can select the desire...

Страница 36: ...ge the name You can switch between the profiles by clicking the appropri ate tab Caution The profiles are rather complex They include a large number of parame ters that interact with one another so it is generally best to use the default profiles Change the profiles only once you are fully familiar with all the configuration options Note All parameters combine to make up a profile and are dependen...

Страница 37: ...ntered here should be at least 10 higher than the value entered in the Target data rate field P frame video quality This setting allows you to adjust the image quality of the P frames depending on the movement within the image The Auto option automatically adjusts to the optimum combination of movement and image definition focus Selecting Man ual allows you to set a value between 4 and 31 on the s...

Страница 38: ...third image etc the frames in between are coded as P frames Encoding interval The figure selected here determines the interval at which images are encoded and transmitted For example entering 4 means that only every fourth image is encoded the following three are skipped this can be particularly advantageous with low bandwidths Video resolution Here you can select the desired resolution for the MP...

Страница 39: ... parameters for recording on the local hard drive Recording can be performed continuously or only in the case of an alarm Partition Select the partition in which you want to record Recording is performed for every video input in a separate partition Activating a partition for recording After configuration you can activate the partition for recording by clicking the Start button ...

Страница 40: ...running will be interrupted and the config uration can be modified Click the Stop all button to deactivate all the partitions set up for the record ing Running recordings are interrupted and the configuration can be changed Time recording You can specify the times during which continuous recording to the hard drive should take place Separate selection fields per partition are available for each da...

Страница 41: ...n the 128 tracks are written old recordings must first be deleted In Ring mode the 129th recording is written in the first track again etc so that the oldest recording is overwritten with the most recent recording Used space on partition This displays how much space is already used in the partition Free space on partition This displays how much space is still available in the partition Recording s...

Страница 42: ...eparate periods for each day of the week Alarm recording occurs only during the highlighted time intervals Note If a period is already selected for time recording you cannot select it for alarm recording see Time recording page 40 Caution Alarm tracks must be set up in the required partition for alarm recording see Number of alarm tracks page 43 The unit uses a special recording mode during alarm ...

Страница 43: ... of alarms entered can be recorded and archived A partition can contain a maximum of 128 alarm recordings If the Ring mode option see page 45 is set for the partition the latest alarm recordings are always saved in the preset number If the Linear mode option is set for the partition the recording stops as soon as all the alarm tracks have been written Pre alarm duration Select the period to be cov...

Страница 44: ...osch Security Systems 2006 07 V1 5 Properties You can view the current properties for the partition selected in each case directly in the recording scheduler and modify them if necessary You can also activate the alarms that should trigger recording Similarly you can also select the profile for recording ...

Страница 45: ...ming compatible units stream 2 is always used for the re cording Type of recording Select the required recording type In the case of Ring mode the recording proceeds continuously If the maximum hard drive space has been reached the oldest recordings are automatically overwritten In the case of Linear mode the recording proceeds until the entire hard drive space is full The recording is then stoppe...

Страница 46: ...the alarm input check boxes correspond to the labeling of the alarm inputs on the rear panel of the unit The motion and video loss alarm numbers correspond to the labeling of the video inputs Partition total size This displays how much storage space the partition occupies on the hard drive Remaining for recording This displays the maximum remaining recording time The value is automatically updated...

Страница 47: ...er to identify The name simplifies the management of multiple units in larger systems for example using the VIDOS program Note The unit name is used for the remote identification of a unit in the event of an alarm for example or to make it easier to call up a unit when using a DNS server Enter a name that makes it as easy as possible to quickly identify the location Unit ID Every unit should be as...

Страница 48: ...nit operates with three user names service user and live which corre spond to different authorization levels The service user name is the highest authorization level After entering the cor rect password this user name allows you to use all the functions of the unit and change all configuration settings The user user name is the middle authorization level You use it to operate the unit and also to ...

Страница 49: ...ote The new password is only saved when you click the Set button You should therefore click the Set button immediately after entering and con firming the password even if you also wish to subsequently assign a pass word to another user name Language Website language Select the language for the user interface here Date and time Date format Select your required date format Europe DD MM YYYY USA MM D...

Страница 50: ...rating on the same time Enter the current date Since the unit time is controlled by the internal clock there is no need to enter the day of the week it is added automatically Enter the current time or click the Synchr PC button to copy your computer s system time to the unit Version information The hardware and firmware version numbers are for information only and cannot be changed Keep a record o...

Страница 51: ...ces and alarm con nections Alarm sources You can configure the possible alarm triggers for the unit for example the alarm inputs Alarm input 1 to Alarm input 10 Select the On option to activate the alarm by the corresponding external alarm sensor Otherwise select Off Select Active high if the alarm is to be triggered by closing the contact Select Active low if the alarm is to be triggered by openi...

Страница 52: ...rigger an alarm A selected video input is indicated by a check mark Note The numbering is the same as the labeling of the video inputs on the rear panel of the unit 1 SNMP host address 2 SNMP host address The unit supports the SNMP Simple Network Management Protocol for man aging and monitoring network components and can send SNMP messages to IP addresses It supports SNMP MIB II and its traps in t...

Страница 53: ...in the event of an alarm Connect on alarm Select On so that the unit automatically connects to a predefined IP address in the event of an alarm Note Dual Streaming compatible units only Stream 2 is always transferred for alarm connections Bear this fact in mind when assigning the profile see page 34 Number of destination IP address Specify the numbers of the IP addresses to be contacted in the eve...

Страница 54: ...after a network failure Note Dual Streaming compatible units only Stream 2 is always transferred for alarm connections Bear this fact in mind when assigning the profile see page 34 Default camera Here you can select the camera whose image will be automatically displayed first on the receiver when the alarm connection is made Depending on the sys tem configuration the receiver can then select the o...

Страница 55: ...IP address subnet mask or gateway address are trans ferred to the unit by clicking Set However they only take effect after the unit is restarted Click Set after entering a new IP address Enter the old IP address followed by reset for example 192 168 0 88 reset in your Web browser s address bar The unit restarts and can then only be accessed at the new IP address Unit IP address Enter the desired I...

Страница 56: ...plex mode FD or HD or 1 GBit s FD Caution Malfunctions such as image faults can occur if the network does not have enough capacity to transmit the maximum data rate generated by the unit Dynamic DNS server IP address When operating a unit on the Internet dynamic addresses are used to ensure efficient use of the available IP address pool That is the unit is reassigned a changing IP address each tim...

Страница 57: ... receivers in a defined group Multicast For each of the eight encoders you can enter a separate multicast address and the relevant port for each stream For Dual Streaming compatible units you can toggle between the streams by clicking the appropriate tab pages Note Multicast operation requires a multicast enabled network that uses the UDP and the Internet Group Management IGMP protocols Other grou...

Страница 58: ... 0 0 the encoder for the relevant stream operates in multi uni cast mode copying of data streams in the unit The unit supports multi unicast connections for up to five simultaneously connected receivers Note Duplication of data places a heavy demand on the unit and can lead to im pairment of the image quality under certain circumstances Multicast port 1 to Multicast port 8 Assign a different port ...

Страница 59: ...rity Systems 2006 07 V1 5 Configuration using a Web browser Note Audio signals are only transmitted if the audio function is activated on the Audio Stream configuration page see page 78 Multicast port 1 audio versions only Enter the port address of the separate audio stream here ...

Страница 60: ...he first re mote location to establish a video connection to the unit is also assigned the transparent data connection However after about 15 seconds of inac tivity the data connection is automatically terminated and another remote location can exchange transparent data with the unit Serial port function Select a controllable unit from the list If you wish to use the serial port to transmit transp...

Страница 61: ...that the value of the Cam era ID must always be selected one less than the Bosch camera number for example Bosch camera number 1 Camera ID 0 Baud rate Select the value for the transmission rate in bit s Data bits The number of data bits per character cannot be changed Stop bits Select the number of stop bits per character Parity check Select the type of parity check Interface mode Select the desir...

Страница 62: ... list If you wish to use the additional RS232 serial interface 9 pin sub D socket to transmit transparent data select Transparent Select Terminal if you wish to operate the unit from a terminal Baud rate Select the value for the transmission rate in bit s Data bits The number of data bits per character cannot be changed Stop bits Select the number of stop bits per character Parity check Select the...

Страница 63: ...ens You can change the settings by entering new values or by selecting a predefined value from a list field Navigation You see the configuration menu as well as the unit overview when you click the SETTINGS link on the LIVEPAGE Click one of the menu items in the left hand margin of the window The associated submenu opens Note The screen display can differ from that shown above depending on the uni...

Страница 64: ... in the current field Changes in any other fields are ignored Unit identification You can give the unit a name and ID to make it easier to identify They both sim plify the management of multiple units in larger systems for example using the VIDOS program Unit name Enter a name for the unit here Note The unit name is used for the remote identification of a unit in the event of an alarm for example ...

Страница 65: ...nit operates with three user names service user and live which corre spond to different authorization levels The service user name is the highest authorization level After entering the cor rect password this user name allows you to use all the functions of the unit and change all configuration settings The user user name is the middle authorization level You use it to operate the unit and also to ...

Страница 66: ...Language You can select the language of the user interface to make the unit easier to use Website language Select the desired language here Date and time If there are multiple devices operating in your system or network it is important to synchronize their internal clocks For example it is only possible to identify and correctly evaluate simultaneous recordings when all units are operating on the ...

Страница 67: ...an receive the time signal of a time server via the Time Server Protocol RFC 868 and set the internal clock accordingly The unit polls the time signal automatically every ten minutes Time zone Select the time zone in which your system is located Time settings Check this box during daylight saving time to include the time change Deacti vate the box again to return to winter time Time server IP addr...

Страница 68: ... the event of an alarm for example It will be displayed in the video screen if config ured to do so see page 69 The camera name is also used by VIDOS the pro gram for managing video surveillance systems and makes it easier to identify the camera there Camera 1 to Camera 8 Enter a unique and clear description as the camera name Note The numbering is the same as the labeling of the video inputs on t...

Страница 69: ...stom option Or it can be set to Off for no overlay information Time stamping This field sets the position of the time overlay It can be displayed at the Top Bottom or at a position of your choice that you have previously defined via HyperTerminal using the Custom option Or it can be set to Off for no overlay information Alarm mode stamping Choose On to display a text message overlay in the event o...

Страница 70: ...played alarm message Enter the message to be displayed for an alarm The maximum text length is 31 characters Video watermarking Choose On if you wish the transmitted video images to be watermarked After activation all images are marked with a small green rectangle A red rectangle indicates that the sequence live or saved has been manipulated ...

Страница 71: ...ctive immediately Click a tab to select the corresponding camera Set the slide bar to the desired position Click Default to reset all settings to their default value Contrast 0 255 You can use this function to adapt the contrast of the video image to your work ing environment Saturation 0 255 You can use this function to adjust the color saturation so as to make the repro duction of colors on your...

Страница 72: ...per ating environment for example network structure bandwidth data load For Dual Streaming compatible units each encoder can create two data streams at the same time with different compression settings such as for transmission and local saving Note The settings must be made individually for each camera input and stream The numbering is the same as the labeling of the video inputs on the rear panel...

Страница 73: ...Modem For analog modem connections at 20 kBit s resolution 352 288 240 pixels Profile 8 GSM For GSM connections at 9600 baud resolution 176 144 120 pixels Active profile for video 1 to Active profile for video 8 Here you can select the desired profile Dual Streaming compatible units only Click a tab to select the relevant stream Select the desired setting from the list Note Dual Streaming compatib...

Страница 74: ...ge number of parame ters that interact with one another so it is generally best to use the default profiles Change the profiles only once you are fully familiar with all the configuration options Note All parameters combine to make up a profile and are dependent on one another If you enter a parameter that is outside the permitted range the nearest permitted value will automatically be substituted...

Страница 75: ...to the optimum combination of movement and image definition focus Selecting Manual allows you to set a value between 4 and 31 on the slide bar The value 4 represents the best image quality with if necessary a lower frame refresh rate depending on the settings for the maximum data rate A value of 31 results in a very high refresh rate and lower image quality I frame video quality This setting allow...

Страница 76: ...4 means that only every fourth image is encoded the following three are skipped this can be particularly advantageous with low bandwidths Video resolution Here you can select the desired resolution for the MPEG 4 video image The following resolutions are available QCIF 176 144 120 pixels CIF 352 288 240 pixels 1 2 D1 352 576 480 pixels 2CIF 704 288 240 pixels D1 4CIF 704 576 480 pixels Reset of pr...

Страница 77: ...urce type input 8 To allow video recorders to be connected as a video source you can change the characteristic of the video source from the preset value of Camera to VCR Video recorders require a more tolerant setting for the internal PLL as a result of jitter effects caused by the mechanical components of a video recorder Note In some cases selecting the Video recorder option can lead to an im pr...

Страница 78: ...utputs can be con nected with the same audio stream Here you can select the audio input and audio output that will be used Enable audio The audio signals are sent in a separate data stream parallel to the video data and so increase the network load The audio data are encoded according to G 711 and require an additional bandwidth of approx 80 kBit s per direction for each connection Select On if yo...

Страница 79: ...utputs Audio 8 Output 8 AO Intercom and Audio Out Stereo out to the same audio stream simultaneously Select the desired audio output from the list Select audio output 8 from the list and check the Intercom box to select the station output AO terminal connector Select audio output 8 from the list and check the Stereo out box to select the Audio Out output via the stereo socket Deactivate the Output...

Страница 80: ...04 576 pixels 4CIF File name You can select which file names will be created for the individual images which are transmitted Overwrite The same file name is always used and any existing file will be overwritten with the current file Increment A number from 000 to 255 is added to the file name and automat ically incremented by 1 When it reaches 255 it starts again from 000 Date time suffix The date...

Страница 81: ...s to be sent FTP server IP address Enter the IP address of the FTP server on which you wish to save the JPEG images FTP login name Enter your login name for the FTP server FTP password Enter the password that gives you access to the FTP server Path on FTP server Enter the exact path on which you wish to post the images on the FTP server Send JPEG from camera Click the check box to activate the cam...

Страница 82: ...oder or camera input camera input Video 1 with partition number 01 camera input Video 2 with partition 02 etc This assignment cannot be modified As a result all numbers are always displayed in the list regardless of whether a corresponding partition is available or has been deleted For recording from eight cameras it is necessary to con figure all eight possible partitions Eight partitions are alr...

Страница 83: ...s been set up you can only create a new partition after deleting at least one of the existing partitions see page 86 Creating a new partition is performed using separate help windows in which information is presented to you and you are led step by step through the neces sary settings The process most be completed for each partition to be set up on the hard drive After starting up the wizard you ca...

Страница 84: ... the text fields to enter values or use the other controls that are avail able such as buttons checkboxes or list fields Click the Next button at the bottom of the window to continue with the next step Click the Back button at the bottom of the window to view the previous step again Click the Cancel button to cancel the process and close the wizard Making changes After you have made all necessary ...

Страница 85: ...dow of the wizard if necessary Click Finish to complete the configuration All settings are now transferred to the unit and subsequently become effective Editing a partition You can modify the configuration of a partition at any time Caution All modifications result in the reorganization of the partition and the loss of all sequences on this partition Changes to the size of a partition Partition to...

Страница 86: ...cations After closing the window click the Set button in the main window to transfer the changes to the unit and to save them Deleting a partition You can delete a partition at any time Caution Deleting a partition leads to the entire hard drive being reorganized and the loss of all sequences stored on the drive Consequently you should check the recordings before deleting any partitions and back u...

Страница 87: ... for every video input in a separate partition Activating a partition for recording After configuration you can activate the partition for recording by clicking the Start button After starting the Time recording Alarm recording and Properties pages for the activated partition are displayed in gray and the configuration cannot be modified The graphic in the lower section of the pages indicates this...

Страница 88: ...can be changed Time recording You can specify the times during which continuous recording to the hard drive should take place Separate selection fields per partition are available for each day of the week allowing settings to be made per camera input You can select up to 16 individual recording time intervals for each day of the week Note If a time interval has already been selected for alarm reco...

Страница 89: ...n the 128 tracks are written old recordings must first be deleted In Ring mode the 129th recording is written in the first track again etc so that the oldest recording is overwritten with the most recent recording Used space on partition This displays how much space is already used in the partition Free space on partition This displays how much space is still available in the partition Recording s...

Страница 90: ...e periods for each day of the week Alarm recording occurs only during the highlighted time intervals Note If a time interval has already been selected for time recording you cannot select it for alarm recording see Time recording page 88 Caution Alarm tracks must be set up in the required partition for alarm recording see Number of alarm tracks page 91 The unit uses a special recording mode during...

Страница 91: ... of alarms entered can be recorded and archived A partition can contain a maximum of 128 alarm recordings If the Ring mode option see page 93 is set for the partition the latest alarm recordings are always saved in the preset number If the Linear mode option is set for the partition the recording stops as soon as all the alarm tracks have been written Pre alarm duration Select the period to be cov...

Страница 92: ...n the recording scheduler and modify them if necessary You can also activate the alarms that should trigger recording Similarly you can also select the profile for recording Caution All modifications result in the reorganization of the partition and the loss of all sequences on this partition Consequently you should back up all important sequences on the comput er s hard drive Partition name You c...

Страница 93: ...space is full The recording is then stopped until old recordings have been deleted Video recording The recording format is displayed here for information Recording profile Select the profile that is to be active during recording You can view and modify the parameters for the profile see MPEG 4 encoder from page 72 Note The recording profile can differ from the standard setting Active profile for t...

Страница 94: ...ow much storage space the partition occupies on the hard drive Remaining for recording This displays the maximum remaining recording time The value is automatically updated after the parameters have been modified Free space on partition This displays how much space is still available in the partition Recording status The graphic indicates the recording activity in this partition You will see an an...

Страница 95: ...ding external alarm sensor Otherwise select Off Select Active high if the alarm is to be triggered by closing the contact Select Active low if the alarm is to be triggered by opening the contact Name You can enter a name for each alarm input which is then displayed below the icon for the alarm input on the LIVEPAGE if configured correctly see Livepage configuration page 112 Video loss alarm Activa...

Страница 96: ...it 1 SNMP host address 2 SNMP host address The unit supports the SNMP Simple Network Management Protocol for man aging and monitoring network components and can send SNMP messages to IP addresses It supports SNMP MIB II and its traps in their full functionality in the unified code If you wish to send SNMP traps enter the IP addresses of one or two required target devices here UDP Port 161 is gener...

Страница 97: ...in the event of an alarm Connect on alarm Select On so that the unit automatically connects to a predefined IP address in the event of an alarm Note Dual Streaming compatible units only Stream 2 is always transferred for alarm connections Bear this fact in mind when assigning the profile see page 72 Number of destination IP address Specify the numbers of the IP addresses to be contacted in the eve...

Страница 98: ...after a network failure Note Dual Streaming compatible units only Stream 2 is always transferred for alarm connections Bear this fact in mind when assigning the profile see page 72 Default camera Here you can select the camera whose image will be automatically displayed first on the receiver when the alarm connection is made Depending on the sys tem configuration the receiver can then select the o...

Страница 99: ... any encoder i e for any connected cam era The sensitivity of the video sensor can be adjusted so that an alarm is generated only if specified values are exceeded Various options for tamper protection allow you to set the reaction to tampering with cameras and video lines In order for the sensor to function the following conditions must be met The motion detector must be enabled At least one senso...

Страница 100: ...guration of the corresponding encoder or camera Enter the desired settings If necessary click the Default button to return all settings to their default values Detector Select On to activate the video sensor The current video standard and the cur rent alarm state are displayed Sensitivity The basic sensitivity of the video sensor can be adjusted for the environmental conditions to which the camera...

Страница 101: ...he objective should trigger an alarm The average brightness of the scene provides a basis for recognition Scene too dark Activate this function if tampering associated with covering the objective for instance by spraying paint on it should trigger an alarm The average brightness of the scene provides a basis for recognition Scene too noisy Activate this function if tampering associated with EMR in...

Страница 102: ...ally open contact You can also specify whether the output should operate as a bistable or monostable relay In bistable mode the triggered state of the relay is main tained In monostable mode you can set the time after which the relay will return to the idle state You can select different events that automatically activate the output It is possi ble for example to turn on a floodlight by triggering...

Страница 103: ... alarm 1 Trigger by interrupting the video signal at the Video 1 input Motion 1 Trigger by motion alarm at Video 1 input Local input 1 Trigger by external alarm input 1 Remote input 1 Trigger by remote station s switching contact only if a connection exists Relay name You can assign a name for the relay here The name is shown on the button next to Trigger relay The Livepage can also be configured ...

Страница 104: ...minated and another remote location can exchange transparent data with the unit Serial port function Select a controllable unit from the list If you wish to use the serial port to transmit transparent data select Transparent Select Terminal if you wish to operate the unit from a terminal Note After selecting a unit the remaining parameters in the window are set au tomatically and should not be cha...

Страница 105: ...lect the value for the transmission rate in bit s Data bits The number of data bits per character cannot be changed Stop bits Select the number of stop bits per character Parity check Select the type of parity check Interface mode Select the desired protocol for the serial interface Half duplex mode Choose the setting appropriate for your application ...

Страница 106: ... list If you wish to use the additional RS232 serial interface 9 pin sub D socket to transmit transparent data select Trans parent Select Terminal if you wish to operate the unit from a terminal Baud rate Select the value for the transmission rate in bit s Data bits The number of data bits per character cannot be changed Stop bits Select the number of stop bits per character Parity check Select th...

Страница 107: ...rted Click Set after entering a new IP address Enter the old IP address followed by reset for example 192 168 0 88 reset in your Web browser s address bar The unit restarts and can then only be accessed at the new IP address Unit IP address Enter the desired IP address for the unit The IP address must be valid for the network Subnet mask Enter the appropriate subnet mask for the selected IP addres...

Страница 108: ...twork does not have enough capacity to transmit the maximum data rate generated by the unit Dynamic DNS server IP address When operating a unit on the Internet dynamic addresses are used to ensure effi cient use of the available IP address pool That is the unit is reassigned a chang ing IP address each time a new connection is made Access is easier if the unit is listed in a DNS server It register...

Страница 109: ...e receivers in a defined group Multicast For each of the eight encoders you can enter a separate multicast address and the relevant port for each stream For Dual Streaming compatible units you can toggle between the streams by clicking the appropriate tab pages Note Multicast operation requires a multicast enabled network that uses the UDP and the Internet Group Management IGMP protocols Other gro...

Страница 110: ... 0 0 the encoder for the relevant stream operates in multi uni cast mode copying of data streams in the unit The unit supports multi unicast connections for up to five simultaneously connected receivers Note Duplication of data places a heavy demand on the unit and can lead to im pairment of the image quality under certain circumstances Multicast port 1 to Multicast port 8 Assign a different port ...

Страница 111: ...guration page see page 78 Multicast port 1 audio versions only Enter the port address of the separate audio stream here Version information The hardware and firmware version numbers are for information only and cannot be changed Keep a record of these numbers in case technical assistance is required Hardware version The hardware version number of the unit is displayed Firmware version The firmware...

Страница 112: ...per part of the window banner Note You can use either GIF or JPEG images The file paths must correspond to the access mode for example C Images Logo gif for access to lo cal files or http www mycompany com images logo gif for ac cess via the Internet Intranet For access via the Internet Intranet ensure that a connection is always available to display the image to be displayed The image file is not...

Страница 113: ...image on the local network Note To restore the original graphics simply delete the entries in the Logo URL and Device logo URL fields Show alarm inputs Alarm inputs are shown next to the video image as icons along with their assigned names If an alarm is active the corresponding icon changes color Show relay outputs audio versions only Relay outputs are shown next to the video image as icons along...

Страница 114: ... in a text file on your local computer You can then view edit and print this file with any text editor or the standard Office software Path for event log Enter the path for saving the event log here If necessary click Search to find a suitable directory Path for system log Enter the path for saving the system log here If necessary click Search to find a suitable directory Path for JPEG and MPEG fi...

Страница 115: ...e wrong files can result in the unit no longer being addressable in which case you must replace the unit You should never interrupt the installation of firmware An interruption can lead to the flash EPROM being incorrectly programmed This in turn can result in the unit no longer being addressable in which case it will have to be replaced First save the update file to your hard drive Enter the full...

Страница 116: ...alog box opens Follow the on screen instructions to save the current settings Configuration upload Enter the full path of the file to upload or click Browse to select the required file Make certain that the file to be loaded comes from the same unit type as the unit you want to configure Next click Upload to begin transferring the file to the unit The progress bar allows you to monitor the transfe...

Страница 117: ...d therefore check that it is functioning correctly after installation and configuration The function test is the only way to ensure that the unit operates as expected in the event of an alarm Your check should include the following functions Can the unit be called up remotely Does the unit transmit all the data required Does the unit react to alarms as desired Is it possible to control peripherals...

Страница 118: ...Installation and Operating Manual VideoJet 8008 VideoJet 8004 EN 118 Configuration using a Web browser Bosch Security Systems 2006 07 V1 5 ...

Страница 119: ...e Components supplied page 9 Instructions for using the Web browser can be found in its online help System requirements Microsoft Internet Explorer version 6 0 or higher Monitor resolution 1024 768 pixels Network access Intranet or Internet Note Also note the information in the System Requirements document on the product CD supplied Installing MPEG ActiveX Note Suitable MPEG ActiveX software must ...

Страница 120: ...t assign it an IP address that is valid in your network The following default address is preset at the factory 192 168 0 1 Start the Web browser Enter the unit s IP address as the URL The connection is established and after a short time you will see the LIVEPAGE with the video image Note The screen display can differ from that shown above depending on the unit variants that you use ...

Страница 121: ... on the unit and network configuration Protected unit If the unit is password protected against unauthorized access the Web browser displays a message to that effect and prompts you to enter the password when you call up access protected areas Note The unit offers the option of limiting access across various authorization levels see pages 48 and 65 Enter the user name and associated password in th...

Страница 122: ...een to the left of the video image To control a peripheral click the appropriate controls Move the mouse cursor over the video image Additional options for control ling peripherals are displayed with the mouse cursor Digital I O In the event of an alarm the green alarm LED for the triggering alarm input appears next to the video image The unit s configuration determines whether the alarm is displa...

Страница 123: ...ese messages automatically in a file see page 114 Audio function audio versions only Depending on the configuration the unit can send and receive audio signals All users who are connected by browsers receive the audio signals sent by the unit Only the user who first connected to the unit can send audio signals to the unit On the LIVEPAGE click anywhere next to the video image to remove the focus f...

Страница 124: ...lick the icon for recording video sequences to start recording The storage location depends on the configuration of the unit see page 114 The flashing red dot in the icon indicates that recording is in progress Click the icon for recording video sequences again to stop recording Image resolution The sequences will be recorded at the resolution specified in the encoder con figuration see pages 38 a...

Страница 125: ...y the MPEGViewer exe file to your computer s hard drive If necessary you can also start the MPEG viewer by double clicking the MPEGViewer exe file Running recording program The hard drive icon below the MPEG video image on the LIVEPAGE changes during an automatic recording on the unit s hard drive by one of the saved pro grams The icon lights up green and displays a moving graphic to indicate a ru...

Страница 126: ...d as a digital video recorder for local long term recording The MEDIA REPLAY page for playing back recorded video sequences can be accessed from the LIVEPAGE and from SETTINGS Click in the navigation bar in the upper section of the window on the MEDIA REPLAY link The playback page appears Note The screen display can differ from that shown above depending on the unit variants that you use ...

Страница 127: ...g a playback You will see a time bar below the video image for quick orientation If a particular sequence has been clicked and selected for playback the selected sequence appears in the list in blue with a green border The associated time interval is displayed in the bar in gray A green arrow above the bar indicates the position of the image currently being played back within the sequence The time...

Страница 128: ...unctions Start playback or pause Jump to the start of active video sequence or to the previous sequence in the list Jump to the end of active video sequence or to the next sequence in the list You can use the slide control to control playback speed and fast forward rewind positioning in the middle indicates playback at recording speed left indicates rewind and right fast forward The fast forward o...

Страница 129: ...ump directly to these These bookmarks are indicated as small yellow arrows above the time interval Use the bookmarks as follows Jump to the previous bookmark Set bookmark Jump to the following bookmark Right click a bookmark to delete it Note Bookmarks are only valid if you remain on the MEDIA REPLAY page they are not saved with the sequences As soon as you leave the page all book marks are delete...

Страница 130: ...nt to save either completely or par tially on the computer s hard drive Click the icon for the sequence backup The backup starts immediately this process is displayed by a flashing red dot in the icon Click the sequence backup icon again to end the backup This procedure can be repeated many times within the sequence to back up multiple extracts from a longer sequence Click the button for backing u...

Страница 131: ...lied page 9 Note Suitable MPEG ActiveX software must be installed on the computer in or der to play back saved video sequences using the MPEG viewer Further information can be found on page 29 Insert the CD into the computer s CD ROM drive If the CD does not start automatically open the CD in Windows Explorer Open the MPEG viewer directory and copy the MPEGViewer exe file to your computer s hard d...

Страница 132: ... Compatible video servers are designed to connect to one another automatically provided they are correctly configured They only need to be part of a closed net work Proceed as follows to install the units Connect the units to the closed network using Ethernet cables Connect them to the power supply Note Make sure that the units are configured for the network environment and that the correct IP add...

Страница 133: ...minal program and enter command i in the main menu to switch to the IP menu In the IP menu enter command r to change the remote IP and enter the IP address of the unit to which you wish to establish a connection In the IP menu enter command a to activate automatic connection Connecting with a Web browser Various requirements must be met in order to operate with a Web browser see page 29 Note The s...

Страница 134: ...n the CONNECTIONS page click the X symbol in the title line of the Monitor window to terminate the display of video images on the connected monitor Operation with decoder software The VideoJet 8008 and VideoJet 8004 video servers combine with the VIDOS program for an efficient system solution VIDOS is a software package for operating controlling and managing CCTV installations such as surveillance...

Страница 135: ...an see the first parameter IP Address and the configured value Press the arrow keys to view other parameters Then press the Menu Exit key to close the menu again Note The Set key is designed for future function extensions Parameters in the display menu Below is a brief description of the parameters available in the display menu IP Address Current IP address of the unit Subnet Mask Current subnet m...

Страница 136: ...rm labeled H EthTX EthRX Current data transmission speed to and from the unit HDD Throughput Current recording speed on the hard drive SW version Firmware version number of the unit HW version Hardware version number of the unit HDD Capacity Current free space on the hard drive COM1 Information on the serial interface standard interface parameters Fan 1 Fan 2 Information on the operating status of...

Страница 137: ...Manual EN 137 Bosch Security Systems 2006 07 V1 5 Operation System uptime Operating time of the unit since the last power on or since the last reset in days hours minutes and seconds Encoder status Indication of the correct operation of the encoder labeled ...

Страница 138: ...Installation and Operating Manual VideoJet 8008 VideoJet 8004 EN 138 Operation Bosch Security Systems 2006 07 V1 5 ...

Страница 139: ...sent and the transmission time in milliseconds If not the unit cannot be accessed over the network This might be because The unit is not properly connected to the network Check the cable connec tions in this case The unit is not correctly integrated into the network Check the IP address the subnet mask and the gateway address Restart Reset If necessary you can restart the unit for example if it no...

Страница 140: ...r dealer s technical service center Transfer and disposal The device should only be passed on together with this installation and operat ing manual Your Bosch product is designed and manufactured with high quality materials and components which can be recycled and reused This symbol means that electrical and electronic equipment at their end of life should be disposed of separately from your house...

Страница 141: ...ou identify the causes of malfunctions and correct them where possible Malfunction Possible causes Solution No connection between the unit and terminal program Incorrect cable connections Check all cables plugs contacts and connections The computer s serial interface is not connected Check the other serial interface Interface parameters do not match If necessary select a different interface and ma...

Страница 142: ...ion is already in use by another receiver Wait until the connection is free and then call the sender again The unit does not report an alarm Alarm source is not selected Select possible alarm sources on the Alarm sources configuration page No alarm response specified Specify the desired alarm response on the Alarm connections configuration page change the IP address if necessary Control of cameras...

Страница 143: ...itched off Lit green Unit is switched on not connected Flashes green 600 ms 50 50 One active connection 300 ms 50 50 Two active connections 150 ms 50 50 Three or more active connections HDD Flashes red Data being transmitted to and from the hard drive Fail Flashes red Hardware error faulty fan Firmware upload failed in connection with VideoJet 8008 DEFAULT or VideoJet 8004 DEFAULT screen display L...

Страница 144: ... Depending on the setting the serial interface uses the RS232 or RS422 485 standards The standard that is used depends on the current configuration see pages 60 and 104 RJ45 socket pin assignment The pin assignment depends on the standard used Contact RS232 standard RS422 485 standard 1 RxD receive data RxD receive data plus 2 CTS clear to send RxD receive data minus 3 4 5 GND ground GND ground 6 ...

Страница 145: ...l interface can be used to transmit transparent data or for using the unit with a terminal program It uses the RS232 standard 9 pin sub D socket pin assignment Contact RS232 standard 1 DCD data carrier detect 2 RxD receive data 3 TxD transmit data 4 DTR data terminal ready 5 GND ground 6 DSR data set ready 7 RTS ready to send 8 CTS clear to send 9 RI ring indication ...

Страница 146: ...gger contact to the ground contact on the left of it when connecting alarm inputs Terminal Function IN1 Input alarm 1 Ground to Input 1 IN2 Input alarm 2 Ground to Input 2 IN3 Input alarm 3 Ground to Input 3 IN4 Input alarm 4 Ground to Input 4 IN5 Input alarm 5 Ground to Input 5 IN6 Input alarm 6 Ground to Input 6 IN7 Input alarm 7 Ground to Input 7 IN8 Input alarm 8 Ground to Input 8 IN9 Input al...

Страница 147: ...using the serial interface include transferring transparent data con trolling connected units or operating the unit with a terminal program Terminal assignment starting at top left Terminal Function R1 Relay output 1 R1 Relay output 1 R2 Relay output 2 R2 Relay output 2 R3 Relay output 3 R3 Relay output 3 R4 Relay output 4 R4 Relay output 4 R5 Relay output 5 R5 Relay output 5 12 V 12 V power suppl...

Страница 148: ...Identification a machine readable character string IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Management Protocol Internet Protocol The main protocol used on the Internet normally in conjunction with the Transfer Control Protocol TCP TCP IP IP See Internet Protocol IP address A 4 byte number uniquely defining each unit on the Internet It is usually written in dotted...

Страница 149: ... A protocol for synchronizing computer clocks over the Internet RS232 RS422 RS485 Standards for serial data transmission RTP Realtime Transport Protocol a transmission protocol for real time video and audio SNMP Simple Network Management Protocol a protocol for network management for managing and monitoring network components Subnet mask See Net mask TCP Transfer Control Protocol Telnet Login prot...

Страница 150: ...isplays 3 LED operating voltage hard drive activity hardware error and display on the front panel 2 LED network connection data transmission to the LAN interface on the rear panel Storage medium 1 160 250 500 GB or 1 TB hard drive Operating conditions Temperature 0 to 40 C 32 to 104 F relative humidity 20 to 80 non condensing altitude 0 to 3 000 m Storage conditions Temperature 20 to 60 C 4 to 140...

Страница 151: ... JPEG Video data rate 1 MBit s to 5 MBit s per channel Image resolutions 704 576 480 pixels 4CIF D1 PAL NTSC 704 288 240 pixels 2CIF 352 576 480 pixels 1 2 D1 352 288 240 pixels CIF 176 144 120 pixels QCIF Overall delay 120 ms PAL NTSC Image refresh rate 1 to 50 60 fields s variable PAL NTSC Field image based encoding Network protocols RTP Telnet UDP TCP IP HTTP IGMP V2 IGMP V3 ICMP ARP ...

Страница 152: ...to 1 2 Vp p 75 Ohm switchable PAL NTSC Dual Streaming Yes Audio inputs Line In 8 3 5 mm stereo socket 1 Vp p max impedance 50 kOhm typ Audio outputs Line Out 8 3 5 mm stereo socket 1 Vp p max impedance 8 Ohm min 1 3 5 mm stereo socket 5 W 8 Ohm 2 5 W 4 Ohm Microphone input 1 push in terminal 2 8 Vp p max at 20 dB impedance 2 kOhm typ supply 2 3 V typ Speaker output 1 push in terminal 6 Vp p max 1 ...

Страница 153: ...9 2 48 6 351 5 mm 16 11 1 91 13 84 inches including feet and BNC connections Weight with HDD 160 GB Approx 5 35 kg Protocols standards Video standards PAL NTSC Video coding protocols MPEG 4 JPEG Video data rate 1 MBit s to 5 MBit s per channel Image resolutions 704 576 480 pixels 4CIF D1 PAL NTSC 704 288 240 pixels 2CIF 352 576 480 pixels 1 2 D1 352 288 240 pixels CIF 176 144 120 pixels QCIF Audio...

Страница 154: ...splays 3 LED operating voltage hard drive activity hardware error and display on the front panel 2 LED network connection data transmission to the LAN interface on the rear panel Storage medium 1 160 250 500 GB or 1 TB hard drive Operating conditions Temperature 0 to 40 C 32 to 104 F relative humidity 20 to 80 non condensing altitude 0 to 3 000 m Storage conditions Temperature 20 to 60 C 4 to 140 ...

Страница 155: ... JPEG Video data rate 1 MBit s to 5 MBit s per channel Image resolutions 704 576 480 pixels 4CIF D1 PAL NTSC 704 288 240 pixels 2CIF 352 576 480 pixels 1 2 D1 352 288 240 pixels CIF 176 144 120 pixels QCIF Overall delay 120 ms PAL NTSC Image refresh rate 1 to 50 60 fields s variable PAL NTSC Field image based encoding Network protocols RTP Telnet UDP TCP IP HTTP IGMP V2 IGMP V3 ICMP ARP ...

Страница 156: ... to 1 2 Vp p 75 Ohm switchable PAL NTSC Dual Streaming No Audio inputs Line In 8 3 5 mm stereo socket 1 Vp p max impedance 50 kOhm typ Audio outputs Line Out 8 3 5 mm stereo socket 1 Vp p max impedance 8 Ohm min 1 3 5 mm stereo socket 5 W 8 Ohm 2 5 W 4 Ohm Microphone input 1 push in terminal 2 8 Vp p max at 20 dB impedance 2 kOhm typ supply 2 3 V typ Speaker output 1 push in terminal 6 Vp p max 1 ...

Страница 157: ...9 2 48 6 351 5 mm 16 11 1 91 13 84 inches including feet and BNC connections Weight with HDD 160 GB Approx 5 3 kg Protocols standards Video standards PAL NTSC Video coding protocols MPEG 4 JPEG Video data rate 1 MBit s to 5 MBit s per channel Image resolutions 704 576 480 pixels 4CIF D1 PAL NTSC 704 288 240 pixels 2CIF 352 576 480 pixels 1 2 D1 352 288 240 pixels CIF 176 144 120 pixels QCIF Audio ...

Страница 158: ...Installation and Operating Manual VideoJet 8008 VideoJet 8004 EN 158 Appendix Bosch Security Systems 2006 07 V1 5 ...

Страница 159: ...mera selection 121 Cameras 20 Changes 33 64 84 Changes in light level 100 Checking network 139 Closing the connection 134 Color depth 10 29 119 COM1 60 104 Components supplied 9 Configuration 29 116 Configuration menu 32 63 Configuration mode 31 Connecting 132 Contrast 71 Control 60 104 Control functions 122 Controlling playback 127 Conventions 5 Creating a partition 83 D Danger 7 Data bits 61 105...

Страница 160: ...ation conditions 17 Installation location 17 Installation overview 19 Installing in a switch cabinet 11 17 18 Interface 14 144 145 Interface mode 61 105 Internal clock 50 66 IP address 26 55 107 J JPEG format 80 JPEG posting 80 JPEG posting interval 81 L Language 49 66 LED 15 Linear mode 41 43 45 89 91 93 Live video images 29 119 LIVEPAGE 112 Loudspeaker 23 Low Voltage Directive 6 M Main functions...

Страница 161: ...ver 11 Receiver password 53 97 Recording parameters 39 Recording profile 45 93 Recording program 125 Recording scheduler 87 Recording status 41 43 46 89 91 94 Recording video sequences 124 Reflections of light 100 Regulations 5 Relay configuration 102 Relay output 23 102 Remote control 12 Repair 8 140 Reset 139 Reset of profile 38 76 Restart 27 139 Ring mode 41 43 45 89 91 93 Router 58 110 RS232 1...

Страница 162: ...rver protocol 67 Time signal 67 Time zone 67 Total size 46 94 Total time 46 94 Transmission parameters 25 Transmission rate 61 62 105 106 Transmission standards 21 23 Transparent 60 62 104 106 Triggering relay 103 TTL 58 110 U Unicast 57 109 Unit date 50 66 Unit ID 47 64 Unit name 47 64 Unit overview 31 33 Unit time 50 66 Upload file 115 URL 30 120 User name 48 65 V Ventilation 18 Version 50 111 V...

Страница 163: ......

Страница 164: ...Systems B V Robert Koch Straße 100 P O Box 80002 85521 Ottobrunn 5600 JB Eindhoven Germany The Netherlands www bosch sicherheitssysteme de www boschsecuritysystems com Copyright 2006 BOSCH Sicherheitssysteme GmbH Subject to change 2908B 0706 en 6 ...

Отзывы: