
Installation and Operating Manual |
VideoJet 8008 / VideoJet 8004
EN
| 142
Appendix
Bosch Security Systems | 2006-07 | V1.5
No connection
established, no
image transmission.
The unit's configuration.
Check all configuration
parameters.
Faulty installation.
Check all cables, plugs, contacts
and connections.
Wrong IP address.
Check the IP addresses (terminal
program).
Faulty data transmission
within the LAN.
Check the data transmission with
ping
.
The maximum number of
connections has been
reached.
Wait until there is a free connection
and then call the sender again.
No audio
transmission to
remote station.
Hardware fault.
Check that all connected audio
units are operating correctly.
Faulty cable connections.
Check all cables, plugs, contacts
and connections.
Incorrect configuration.
Check the configuration of the
audio settings (gain and
activation).
Audio voice connection is
already in use by another
receiver.
Wait until the connection is free and
then call the sender again.
The unit does not
report an alarm.
Alarm source is not selected. Select possible alarm sources on
the
Alarm sources
configuration
page.
No alarm response
specified.
Specify the desired alarm response
on the
Alarm connections
configuration page, change the
IP address if necessary.
Control of cameras
or other units is not
possible.
The cable connection
between the serial interface
and the connected unit is not
correct.
Check all cable connections and
ensure all plugs are properly fitted.
The interface parameters do
not match those of the other
unit connected.
Make sure that the settings of all
units involved are compatible.
The unit is not
operational after a
firmware upload.
Power failure during
programming by the update
file.
Have the unit checked by
Customer Service and replace if
necessary.
Incorrect update file.
Enter the unit's IP address followed
by
/main.htm
in the Web browser
and repeat the upload.
Malfunction
Possible causes
Solution
Содержание VideoJet 8004
Страница 1: ...VideoJet 8008 VideoJet 8004 ...
Страница 138: ...Installation and Operating Manual VideoJet 8008 VideoJet 8004 EN 138 Operation Bosch Security Systems 2006 07 V1 5 ...
Страница 158: ...Installation and Operating Manual VideoJet 8008 VideoJet 8004 EN 158 Appendix Bosch Security Systems 2006 07 V1 5 ...
Страница 163: ......