18
en | Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts
AutoDome 600 Series Analog PTZ Camera
F.01U.265.793 | 2.0 | 2012.02
Installation Manual
Bosch Security Systems, Inc.
1.
Route all video, control, and alarm wires through the conduit fitting on the right side of
the power box. Refer to
Section 5 Cable and Wire Standards, page 67
, for wire
specifications and distances.
2.
Route the high voltage 115/230 VAC lines through the conduit fitting on the left side of
the box. The Power Supply Box with a transformer comes with a barrier that separates
the high voltage side on the left, from the low voltage 24 VAC side on the right.
3.
Cut and trim all wires with sufficient slack to reach their connector terminals in the box,
but not so long as to be pinched by or to obstruct closing the Pendant Arm. Refer to
Figure 2.3, Page 17
, above, for the connector locations.
4.
Attach the supplied 3-pin Power Plug to the incoming power wires. Refer to connector
P101 in
Table 2.1, Page 21
, for wire connections.
5.
Attach the supplied 6-pin Control Data I/O Plug to the incoming control wires. Refer to
connector P106 in
Table 2.1, Page 21
, for wire connections. This step is not required with
Fiber Optic models, since control passes through the fiber optic cable.
6.
Attach a BNC connector to the incoming video coax cable. If using UTP for video attach
an RJ45 plug to the incoming UTP cable. If installing a Fiber Optic model, attach an ST
fiber plug to the optic fiber cable. Refer to
Section 5 Cable and Wire Standards, page 67
,
for the different methods of transmitting video and control protocols, and wire
specifications.
Note:
Do not connect the RJ45 connector unless using UTP video.
7.
If using a coax cable, connect the incoming coax cable to the BNC jack (female connector
enclosed by the plastic cover) on the coax cable with ferrite. Slide the plastic cover over
the connection. Refer to
Section 2.4.1 Coaxial Cable Connections, page 17
.
NOTICE!
If “daisy chaining” a series of AutoDomes, a terminating resistor is required in the last dome of
the series. The Bosch Power Supply Box is supplied with a 100 Ω terminating resistor located
between the Biphase terminals C- and C+ (pins 1 and 2) of the P106 control connector.
Remove the resistor from all but the last AutoDome power box. The maximum number of
AutoDomes that can be daisy chained is four (4). If using the RS485 protocol for control, the
terminating resistor must be moved from the Biphase C+ and C- (pins 1 and 2) terminals to
the RXD- and TXD+ terminals (pins 4 and 5) of the P106 control connector of the last
AutoDome power box.
Содержание VG5 600 Series
Страница 1: ...AutoDome 600 Series Analog PTZ Camera VG5 600 Series en Installation Manual ...
Страница 2: ......
Страница 87: ......