Страница 3: ...Power Supply Box 26 2 8 Installing the VG4 A ARMPLATE 27 2 8 1 Attach the Pendant Arm to the Mounting Plate 29 2 8 2 Route and Connect Wires to a Power Supply Box 30 2 9 Prepare Pendant for Installation 32 2 10 Attach Pendant to Arm and Tighten 34 3 Installing the Roof Parapet and Pipe Mounts 36 3 1 Unpacking 36 3 1 1 Parts List 36 3 1 2 Description 36 3 1 3 Tools Required 36 3 2 Pre installation ...

Страница 4: ...ng Coaxial Cable to Transmit Video and Control 67 5 3 2 Using UTP to Transmit Video and Control 68 5 3 3 Using Multi mode Fiber Optic to Transmit Video and Control 69 5 4 Control only Cables 69 5 4 1 Controlling the AutoDome via Biphase 69 5 4 2 Controlling the AutoDome via the RS232 Protocol 71 5 4 3 Controlling the AutoDome via the RS485 Protocol 72 5 5 Fiber Optic Module with an RS232 RS422 Con...

Страница 5: ... 01U 265 793 2 0 2012 02 7 Bubble Handling and Cleaning 80 7 1 Handling 80 7 2 Cleaning 80 7 2 1 Cleaning the Bubble Interior 80 7 2 2 Cleaning the Bubble Exterior 81 A Installation Notes for AutoTracker 82 A 1 Camera Height 82 A 2 Mount Mounting Surfaces 83 A 3 Field of View 83 A 4 Unwanted Motion 83 Index 84 ...

Страница 6: ...ush objects of any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electrical shock Never spill liquid of any kind on the unit Do not place objects filled with liquids such as vases or cups on the unit 6 Lightning For added protection during a lightning storm or when leaving this unit unattended and unused for long p...

Страница 7: ... requiring service Unplug the unit from the main AC power source and refer servicing to qualified service personnel when any damage to the equipment has occurred such as the power supply cord or plug is damaged exposure to moisture water and or inclement weather rain snow etc liquid has been spilled in or on the equipment an object has fallen into the unit unit has been dropped or the unit cabinet...

Страница 8: ...of the power supply connector see section Connecting external power supply Camera lens An assembled camera lens in the outdoor housing must comply and be tested in accordance with UL IEC60950 Any output or signal lines from the camera must be SELV or Limited Power Source For safety reasons the environmental specification of the camera lens assembly must be within the environmental specification of...

Страница 9: ...S MOS FET handling precautions to avoid electrostatic discharge NOTE Wear required grounded wrist straps and observe proper ESD safety precautions when handling the electrostatic sensitive printed circuit boards Fuse rating For security protection of the device the branch circuit protection must be secured with a maximum fuse rating of 16A This must be in accordance with NEC800 CEC Section 60 Grou...

Страница 10: ... cause harmful interference and this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules and ICES 003 of Industry Canada These limits are designed to provide reasonable protection against harmful interference wh...

Страница 11: ...entify and Resolve Radio TV Interference Problems Comment identifier et résoudre les problèmes d interférences de radio et de télévision Cette brochure est disponible auprès du U S Government Printing Office Washington DC 20402 États Unis sous la référence n 004 000 00345 4 AVERTISSEMENT Ce produit est un appareil de Classe A Son utilisation dans une zone résidentielle risque de provoquer des inte...

Страница 12: ...t Telephone 800 326 1450 Fax 585 223 3508 or 717 735 6560 Email technical support us bosch com Repair Center Telephone 585 421 4220 Fax 585 223 9180 or 717 735 6561 Email security repair us bosch com Canada Telephone 514 738 2434 Fax 514 738 8480 Europe Middle East Asia Pacific Region Please contact your local distributor or Bosch sales office Use this link http www boschsecurity com startpage htm...

Страница 13: ...king carton is the safest container in which to transport the unit and must be used if returning the unit for service Save it for possible future use 2 1 1 Parts List The following table lists the optional parts you may need for attaching a Pendant to the Arm Wall Corner or Mast mount packages Mounting Options Part Numbers Pendant Arm Only VGA PEND ARM Pendant Arm with Mounting Plate 24 V VG5 mode...

Страница 14: ...reliefs for conduits to the Power Supply Box to ensure that water cannot enter the box You must use water tight conduits and fittings to meet NEMA 4 standards 3 Route all rough wiring including power control video coax alarms I O relay I O and fiber optic cabling Refer to Section 5 Cable and Wire Standards page 67 for video and control protocol methods 4 If you plan to use the RS232 or RS485 proto...

Страница 15: ...iring the box through the back move the two 2 seal plugs to the bottom through the holes before mounting Figure 2 1 Power Supply Wall Mast Pole and Corner Mounts 1 Use the wall mount template supplied in the packaging box to locate the four 4 mounting holes for the Power Supply Box 2 Drill four 4 holes for the mounting anchors If installing outdoors apply a weatherproof sealant around each hole at...

Страница 16: ...e Power Supply Box through which you will run the power video and control data wires 2 4 Route Wires and Attach Connectors Power wires must be routed to the left front side of the Power Supply Box through a separate conduit All video control and alarm wires must be routed through a second conduit to the right side of the box If you plan to route the power through an intermediate power supply box r...

Страница 17: ...ing illustration shows the components of this cable Figure 2 2 Coaxial cable with ferrite You must connect the incoming coax cable from the head end to the BNC jack item 4 above on the ferrite cable and connect the BNC plug item 1 of the ferrite cable to the BNC connector from the AutoDome pendant arm 2 4 2 Make the Connections Figure 2 3 Pendant Arm Power Supply Box 1 BNC Plug male connector 2 Fe...

Страница 18: ...ber Optic models since control passes through the fiber optic cable 6 Attach a BNC connector to the incoming video coax cable If using UTP for video attach an RJ45 plug to the incoming UTP cable If installing a Fiber Optic model attach an ST fiber plug to the optic fiber cable Refer to Section 5 Cable and Wire Standards page 67 for the different methods of transmitting video and control protocols ...

Страница 19: ...incoming wires Refer to Figure 2 4 Page 19 above for the wire connections Refer to Section 6 Alarms and Relay Connections page 76 for more details about wiring alarms and relays 1 4 pin Alarm Connector P102 2 6 pin Alarm In Connector P103 3 7 pin Relay Connector P104 Pin Description Pin Description Pin Description 1 Alarm Out 1 1 Alarm In 3 1 Normally Open 2 Alarm Out 2 2 Alarm In 4 2 COM 3 Alarm ...

Страница 20: ...ut 4 Video 9 P105 Connector Control to Dome 4a UTP Ethernet Ethernet for VG5 700 Series only 10 Power In 3 4 in 20 mm NPS Fitting 5 24 VAC to Dome 11 Control Data and Video In Out 3 4 in 20 mm NPS Fitting TRANSFORMER 115 230VAC MODELS P101 1 2 3 6 5 4 3 2 1 6 5 4 3 2 1 P106 XF102 XF103 XF101 J103 J103 J J 103 J102 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 J101 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LED P10...

Страница 21: ...nector from the VG4 PSU1 or VG4 PSU2 does not match to the 3 pin power input of the VG4 PA0 power supply The illustration below depicts A VG4 PSU1 VG4 PSU2 Power Supply Box The main power supply connected to the P101 connector and to the grounding screw The 24 VAC power out wire connected to the P107 heater power connectors No Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Ground Grounding Screw P1...

Страница 22: ...ons 1 120 230 VAC Power In 5 Transformer 2 Ground Wire 6 In Out Conduit 1 2 in 15 mm NPS Fitting 3 P101 Connector 7 24 VAC Power Out to VG4 PA0 4 P107 Connector No Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Ground Grounding Screw P101 115 230 VAC Power In Line NC Neutral P107 24 VAC Power Out Earth Ground Heater 24 VAC Heater 24 VAC GND TXD RXD C C GND TXD RXD C C P101 1 2 3 6 5 4 3 2 1 6 5 4 3...

Страница 23: ...er supply 4 Attach the ground wire to the grounding screw 5 Connect three wires to the P107 Power Out connector to route the 24 VAC power supply to the VG4 PA0 Power Supply Box a Connect the first wire to pin 5 HN Heater Neutral connector b Connect the second wire to pin 4 HL Heater Line connector c Connect the third wire to pin 3 Earth Ground connector Refer to connector P107 in Table 2 2 and to ...

Страница 24: ...0 Power Supply Box 9 Follow the instructions in Section 2 6 Attach Pendant Arm to Power Supply Box page 25 to continue the installation 1 Incoming 24 VAC Power Supply Wires from VG4 PSU1 VG4 PSU2 power supply box 2 Ground Wire 3 P101 Connector 4 Control Data and Video In Out Wires GND TXD RXD C C GND TXD RXD C C P101 1 2 3 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 4 5 4 4 5 4 4 5 5 6 5 4 3 2 1 2 1 6 5 4 3 3 3...

Страница 25: ...hing its pin lever up and holding it 3 While continuing to hold the top hinge pin open and align the top and bottom hinges of the Pendant Arm to their mating points on the Power Supply Box See Figure 2 10 above for an illustration 4 Once you have the hinges aligned release the top hinge pin to engage its mating hinge on the power box Then release the bottom hinge pin from the Hinge Pin Stop to loc...

Страница 26: ...the grounding screw on the left side of the power box 2 Connect the 6 pin Control In Out Plug installed previously to its mating connector P106 in the power box If this product is a Fiber Optic model this step is not required since all control data is sent through the fiber cable 3 Connect the 6 pin Control to Dome Plug from the Pendant Connector Harness to its matting connector P105 in the power ...

Страница 27: ...grounding strap of the Pendant Arm to the Power Supply Box Refer to Figure 2 11 10 After making the harness connections to the Power Supply Box rotate the Pendant Arm to close and seal the Power Supply Box and tighten the two 2 captive screws to 10 12 N m 90 105 in lbs 11 Refer to Section 2 10 Attach Pendant to Arm and Tighten page 34 to continue the VG5 AutoDome Installation procedure 2 8 Install...

Страница 28: ...onnector through which you route the wires that connect to the pendent arm a Follow the instructions provided with the banding tool to securely mount the Mast Plate to the pole Contact your Bosch Sales Representative to order Banding Tool P N TC9311PM3T b Secure the Mounting Plate to the Mast Plate using the four 4 3 8 x 1 3 4 inch bolts and split lock washers supplied c Remove one of the rubber g...

Страница 29: ...Hinge Pin Stop Figure 2 12 Connect Pendant Arm to Mounting Plate 2 Open the top hinge by pushing its pin lever up and holding it Note Both Hinge Pins must be fully compressed to open unlock the hinges of the Pendant Arm and before proceeding to the next step 3 While continuing to hold the top hinge pin open align the top and bottom hinges of the Pendant Arm to their mating points on the Mounting P...

Страница 30: ... and Connect Wires to a Power Supply Box The illustration below depicts the power and control cables connected to the Pendant Arm Figure 2 13 Pendant Arm Cables Cable Cable 1 Grounding Strap black 5 UTP Video Ethernet blue Ethernet for VG5 700 Series only 2 24 VAC Power red 6 Alarm Outputs white 3 Relay Contacts yellow 7 Alarm Inputs gray 4 Coax Video black 8 Serial Communications green ...

Страница 31: ...ating connector item 1 Figure 2 14 to the other spade terminal inside the mounting plate 6 Attach the 5 pin Power In mating connector to the 24 VAC Power cable cable 2 connected to the pendant 7 Remove the mating connector from the Relay Contacts cable cable 3 8 Connect the incoming relay contact wires to the mating connector Then reattach the mating connector to the Relay Contacts cable 9 Attach ...

Страница 32: ...Biphase C terminals receive a line input audio signal Refer to Section 5 Cable and Wire Standards page 67 for detailed wire and connection information 16 Attach the 6 pin serial communication mating connector to the Serial Communication cable 8 cable 17 Connect the Earth ground wire if available to the crimp ring terminal inside the Mounting Plate Refer to Figure 2 14 above Note The Earth ground i...

Страница 33: ...t Bubble Release Opening 6 Remove the foam inserts surrounding the camera module 7 If you plan to use the RS232 or the RS485 protocol to control the dome refer to either Section 5 4 2 Controlling the AutoDome via the RS232 Protocol page 71 or Section 5 4 3 Controlling the AutoDome via the RS485 Protocol page 72 for instructions Then proceed to the next step 8 Re insert the Bubble assembly into the...

Страница 34: ... arm base and place the mounting hook located on top of the dome housing over the recessed hinge pin of the arm Figure 2 16 Attach Pendant to Arm NOTICE Before attaching the AutoDome Pendant visually inspect the dome and arm connectors for any blocked pin holes or bent pins 1 Tilt up 2 Hook and drop 2a Recessed Hinge Pin 2b Dome Connector 3 Rotate down to engage dome connector 4 Tighten the two 2 ...

Страница 35: ... housing down to a vertical position and gently push upward to engage the connector on top of the dome housing 4 Hold the Pendant housing in position while tightening the two 2 5 mm Allen head mounting screws on top of the housing to 10 12 N m 90 105 in lbs CAUTION If you feel any resistance when rotating the dome housing or when engaging the connector stop immediately and start over CAUTION You m...

Страница 36: ...er to Section 2 Installing the Pendant Arm Wall Corner and Mast Pole Mounts if you are installing a Pendant Arm to a Wall Corner or Mast or pole or refer to Section 4 Installing the In Ceiling Mount if you are mounting an In ceiling AutoDome The VG4 A 9230 Series are stationary mounts intended for rooftop parapet vertical walls They are made of light weight aluminum with a corrosion resistant fini...

Страница 37: ... via the RS485 Protocol page 72 for instructions on configuring the AutoDome to accept these protocols 5 Choose the appropriate VG5 AutoDome model indoor or outdoor for the environment in which it will be used 6 If this AutoDome installation utilizes the AutoTracker feature refer to Section A Installation Notes for AutoTracker page 82 before mounting the AutoDome 7 Purchase the appropriate mountin...

Страница 38: ...2 Drill four 4 holes for the mounting anchors If installing outdoors apply a weatherproof sealant around each hole at the mounting surface 3 Place the Power Supply Box into the optional Trim Skirt 4 Secure the Power Supply Box to the wall using four 4 corrosion resistant stainless steel studs not included 5 Attach the 3 4 in 20 mm watertight pipe fittings not supplied to the holes of the Power Sup...

Страница 39: ... the female hinges of the Cover Door before proceeding to the next step 3 While holding the top hinge pin open position the Cover Door to the Power Supply Box and align its hinges 4 When the hinges are aligned release the top hinge pin to engage its mating hinge on the power box Then release the bottom hinge pin from the Hinge Pin Stop to complete attaching the Cover Door to the Power Supply Box 1...

Страница 40: ...wer Supply Box and out to the AutoDome Interface Board Figure 3 3 VG4 A PSU1 or VG4 A PSU2 Power Supply Box WARNING External interconnecting cables are to be installed in accordance to NEC ANSI NFPA70 for US application and Canadian Electrical Code Part I CSA C22 1 for CAN application and in accordance to local country codes for all other countries Branch circuit protection incorporating a 20 A 2 ...

Страница 41: ...VAC Power In 7 P101 Connector 2 P101 Connector 8 P107 Connector 3 Ground Connection 9 24 VAC Power In to AutoDome 4 Transformer 10 Earth Ground 5 24 VAC Power Out 11 24 VAC Power In to AutoDome 6 P107 Connector 12 24 VAC Power In to Heater 13 24 VAC Power In to Heater 14 AutoDome Power 15 Heater Power GND TXD RXD C C GND TXD RXD C C P101 P106 P105 P107 XF102 XF103 XF101 5 4 3 2 1 J J J 103 J102 J1...

Страница 42: ...incoming high voltage power wires in the box Refer to connector P101 in Table 3 1 Page 45 4 If you are using UTP for video route the UTP cable out to where the AutoDome will be mounted Refer to Section 5 Cable and Wire Standards page 67 for fiber optic specifications 5 Route the low power 24 VAC wires from the right side of the Power Supply Box out to where the AutoDome will be mounted Attach the ...

Страница 43: ... Fiber Optic Module in the power supply box Refer to Section 5 Cable and Wire Standards page 67 for fiber optic specifications 3 Route the control wires from the Power Supply to the Pipe Interface Board Then attach the supplied six 6 pin control data connector to the wires in the Power Supply Box NOTICE You will need a barrel connector not supplied to connect the BNC connector from the Pipe Interf...

Страница 44: ... 3 4 in 20 mm NPS Fitting 4 24 VAC to Dome Interface Board 8 Control Data and Video In Out 3 4 in 20 mm NPS Fitting CONTROL TO DOM E M M CONTROL IN OUT GND TXD RXD C C P101 1 2 3 6 5 4 3 2 1 3 P106 P105 P107 XF102 XF103 XF101 5 4 3 2 1 J103 J103 J J 103 J102 1 1 1 1 1 J101 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LED 6 5 4 3 2 1 GND TXD RXD C C HTR DOME FUSE FUSE FUSE 24V NC 2...

Страница 45: ...onnector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Ground Grounding Screw P101 115 230 VAC or 24 VAC Power In Line NC Neutral P1051 Control to Dome Fiber Optic Model C Biphase C Biphase Earth Ground RXD RS 232 485 TXD RS 232 485 Signal Ground P1061 Control In Out Optional C Biphase C Biphase Earth Ground RXD RS 232 485 TXD RS 232 485 Signal Ground P107 24 VAC Power to Dome Plug Dome 24 VAC Dome 24 VAC E...

Страница 46: ...nd then attach the Parapet Wall Bracket to the Roof Mount Plate 1 Pipearm 4 Apply sealant around each fastener hole 2 Parapet Wall Bracket 5 Roof Mount Plate 3 3 8 16 SS Hex Head Bolt supplied 6 Use a minimum of six 6 fasteners not supplied Eight 8 fastener holes shown NOTICE Fasteners are not supplied with the Roof Parapet Mount Kit since it depends on the material to which it is attached The mat...

Страница 47: ...ure 3 7 VG4 A 9230 Parapet Mount 7 Fold the video control and power wires back at the front end of the arm and route them down and out through the Down Pipe Then replace the End Cap 8 Wrap at least five layers of Teflon tape around the Down Pipe threads 9 Apply the supplied thread sealant to the Down Pipe threads Make sure all surfaces are clean and dry Apply a bead of sealant completely around th...

Страница 48: ... seal any gaps between the down pipe and the Dome Cap 12 Proceed to Section 3 7 Wire the Pipe Interface Board page 50 WARNING You must thread the Dome Cap onto the Down Pipe until it is tight Failure to do so can result in damage serious injury or death 1 Thread Sealant or tape 2 Dome Cap NOTICE Use a guy wire to aid in stabilizing the Parapet Arm Replace the 1 4 inch cap screw with a threaded 1 4...

Страница 49: ...own the pipe 5 Wrap at least five layers of Teflon tape around the threads 6 Apply the supplied thread sealant to the threads on the Pipe Make sure all surfaces are clean and dry Apply a bead of sealant completely around the leading threads of the male fitting Force the adhesive into the threads to thoroughly fill all voids 7 Thread the Pipe Cap onto the down pipe and tighten securely to prevent l...

Страница 50: ...This section provides instructions for connecting wires and cables to the Pipe Interface Board as illustrated below Refer to Section 5 Cable and Wire Standards page 67 for cable and wiring recommendations and specifications Figure 3 10 Pipe Interface Board Connections BNC 7 5 6 4 3 2 1 2 1 2 1 3 J102 P107 P101 P102 P103 P104 P106 J101 AGND A7 A6 A5 A4 A3 AGND OUT 3 OUT 2 OUT 1 1 2 3 4 5 6 P105 ...

Страница 51: ...a image and power wires Follow the procedures below to make the proper connections 1 Attach a BNC connector to the incoming video coax cable Connect the incoming coax cable to its mating connector J102 on the Pipe Interface Board 2 If using UTP for video attach an RJ45 connector plug to the UTP cable and connect the plug to its mating connector J101 on the Pipe Interface Board Ref Description Conn...

Страница 52: ...e appropriate alarm wires Then connect the plugs to their mating connectors P103 and P102 on the Pipe Interface Board Figure 3 11 Alarm and Relay Connector Plugs CAUTION To protect the AutoDome from damage due to cold temperatures ensure that you connect the 24 VAC heater power wires to the P101 connector 1 4 pin Alarm Connector P102 2 6 pin Alarm In Connector P103 3 7 pin Relay Connector P104 Pin...

Страница 53: ... The inside of the pendant housing contains packing material to safeguard the camera during shipping You must remove the packing material before attaching the pendant to the mount by removing the bubble 1 Open the top of the box containing the pendant housing and remove the top foam insert 2 Remove the pendant housing from the box and from the plastic bag and place the pendant housing back into th...

Страница 54: ... Release Opening 6 Remove the foam inserts surrounding the camera module 7 If you plan to use the RS232 or the RS485 protocol to control the dome refer to either Section 5 4 2 Controlling the AutoDome via the RS232 Protocol page 71 or Section 5 4 3 Controlling the AutoDome via the RS485 Protocol page 72 for instructions Then proceed to the next step 8 Re insert the Bubble assembly into the Pendant...

Страница 55: ... dome and the Interface Board connectors for any blocked pin holes and bent pins 2 Tilt the Pendant enough to place its mounting hook on top of the its housing over the recessed hinge pin of the Dome Cap Figure 3 14 Pendant to Roof Pipe Mount Attachment 1 Tilt Dome 2 Hook and drop 2a Dome Cap 2b Recessed Hinge Pin 2c Dome Connector 3 Rotate down to engage dome connector 4 Tighten the two 2 mountin...

Страница 56: ...arth ground wire to the grounding screw on the left side of the box 2 Connect the 24 VAC to Dome plug installed previously to its mating connector P107 on the right side of the box 3 Connect the 115 230 VAC 3 pin Power in plug installed previously to its matting connector P101 on the left side of the box 3 10 1 Connections for Fiber Optic Models The following procedure references Figure 3 6 Page 4...

Страница 57: ...rts List The following table lists the parts included with the In ceiling mount packages 4 1 2 Description This chapter details how to install the AutoDome in an In Ceiling Mount The In Ceiling AutoDome camera is suitable for use in environmental air spaces Refer to Section 2 Installing the Pendant Arm Wall Corner and Mast Pole Mounts or refer to Section 3 Installing the Roof Parapet and Pipe Moun...

Страница 58: ...rotocol to control the AutoDome refer to Section 5 4 2 Controlling the AutoDome via the RS232 Protocol page 71 or Section 5 4 3 Controlling the AutoDome via the RS485 Protocol page 72 for instructions on configuring the AutoDome to accept these protocols 4 A minimum of 216 mm 8 1 2 inch of air space above the ceiling is required to install the In ceiling Mount 5 If this AutoDome installation utili...

Страница 59: ...g housing into a suspended or drop ceiling This kit requires a separate purchase 1 Choose the desired location to mount the dome and remove an adjacent ceiling tile 2 Loosen the four 4 securing screws located in the corners of the Bracket Assembly enough to hold the suspension bars but still allowing adjustment during installation 3 Place the Bracket Assembly over the ceiling tile which is used to...

Страница 60: ...r routing all video control power and alarm wires 1 Attach a 3 4 inch NPS 20 mm conduit fitting to the hole in which you bring in the wires Be sure to thread the inside nut to the conduit fitting 2 Route the video control power and alarm wires through the conduit fitting and into the Interface Box 3 Cut and trim the wires allowing for sufficient slack to their respective terminals in the box 4 Att...

Страница 61: ...nector on the Pipe Interface Board Refer to Section 6 Alarms and Relay Connections page 76 for more details on wiring alarms 9 Attach the lid to the Interface box a Align the slots on the lid with the two posts at the rear of the Interface box b Rotate the lid down c Squeeze the ground clips located at the front of the box against the Interface box with your fingers before closing the lid to ensur...

Страница 62: ... following figure is a detailed illustration of the In ceiling Interface box Figure 4 7 In ceiling Interface Box 1 Fiber Optics 5 Coax Video 2 UTP Ethernet Video Ethernet for VG5 700 Series only 6 Alarm In 3 Dome Power 7 Analog In 4 Data In Out 8 Relay P105 P104 P102 P103 J101 J102 24VAC 24VAC P101 SIG GND TXD RXD C C NC NO COM AGND A2 A1 J103 A3 A4 A5 A6 A7 AGND AGND OUT3 OUT2 OUT1 ...

Страница 63: ...he In Ceiling Housing See the figure below for an illustration Figure 4 8 Bubble Release Screw 3 Remove the foam inserts surrounding the camera module 4 If you plan to use the RS232 or the RS485 protocol to control the dome refer to either Section 5 4 2 Controlling the AutoDome via the RS232 Protocol page 71 or Section 5 4 3 Controlling the AutoDome via the RS485 Protocol page 72 for instructions ...

Страница 64: ...by two 2 thumbscrews Figure 4 10 Attach Housing to Interface Box 1 Insert the In ceiling housing through the hole in the ceiling to verify that the edge of the hole support the unit Then remove the housing from the hole 2 Align the ball studs of the In Ceiling Housing to the Stud Retainers on Interface Box and attach NOTICE The dome bubble comes assembled with a white trim ring An optional black t...

Страница 65: ...g Figure 4 11 In Ceiling Housing and Interface Box 1 Interface Box 4 Thumb Screw 2 Ball Stud 5 Tether Point 3 In ceiling Housing 6 Ceiling Clamp CAUTION The In ceiling dome is provided with tether points on each side of the housing To prevent injury attach a safety wire from a secure anchor point above the ceiling to a tether point on the dome housing refer to Figure 4 12 Page 66 below for an illu...

Страница 66: ...iling 2 Tighten both clamps using a 2 Phillips screwdriver to secure the housing to the ceiling Figure 4 12 Secure Dome to Ceiling 1 Tether Point 4 Ceiling Clamp 2 Ceiling Clamp 5 Rotate Clockwise to Engage Clamp 3 Tether Point mm inches 41 7 MAX 1 64 CEILING 12 7 MIN 0 50 CEILING CAUTION Over torquing the Ceiling Clamps can damage the clamp or ceiling Only tighten the clamp until it contacts the ...

Страница 67: ...cordance with the National Electrical Code or applicable local codes CAUTION All wires for installation applications must be routed through a grounded conduit 115 230 VAC Copper Wire To comply with local codes 24 V to AutoDome VA Watts 14 AWG 2 5 mm 16 AWG 1 5 mm 18 AWG 1 0 mm AutoDome 600 Indoor 27 15 129 m 422 ft 81 m 265 ft 51 m 167 ft AutoDome 600 Outdoor1 55 51 63 m 207 ft 40 m 130 ft 25 m 82...

Страница 68: ...on or Pre Comp which extends the normal range of control from the head end The following figure illustrates the connections necessary to transmit video and control over a UTP cable Figure 5 1 Video and Control over UTP Size O D between 4 6 mm 0 181 in and 7 9 mm 0 312 in Shield Copper braid 95 Central Conductor Standard copper center Terminal Connector BNC Cable Compensation Maximum Distances Vide...

Страница 69: ...r The AutoDome has a 100 Ω termination resistor between the Biphase C and C terminals Multimode Fiber Type 50 125 µm 62 5 125 µm low loss multimode glass fiber Maximum Distance 4 km 2 5 miles Minimum Bandwidth 20 MHz Video 850 nm Control 1300 nm Requirement Bosch LTC 4629 Fiber Receiver at controller end of system Terminal Connector ST Singlemode Fiber Type 9 125 µm low loss single glass fiber Max...

Страница 70: ...he 100 Ω resistor must be removed from all but the last dome You can daisy chain a maximum of four 4 AutoDomes Figure 5 3 Connections for a Daisy Chain Configuration 1 C Biphase 7 AutoDome Data In Out 2 C Biphase 8 Head End Biphase 3 Earth Ground 9 P105 P106 Connector 4 RxD 10 C Biphase 5 TxD 11 C Biphase 6 Signal Ground 12 Shield 1 C Biphase 9 Dome 3 2 C Biphase 10 Dome 2 3 Earth Ground 11 Dome 1...

Страница 71: ...eiver at relatively slow baud rates up to 57 6 Kbaud and short distances up to 50 ft Figure 5 4 Connections for RS232 Operation NOTICE After making the wire connections for RS232 operation reposition the slide switch located on the CPU Module to the camera head inward and away from the LEDs Wire Type 3 wire TXD RXD common Distance 15 m 50 ft Maximum Baud Rate 57 6 Kb Voltage 15 V Termination 100 Ω...

Страница 72: ...ugh RS485 can be connected in a 2 or 4 wire mode 1 Switch Location 2 LEDs 3 RS232 4 CPU Module NOTICE The wire shield must be tied to signal at both ends if 2 wire twisted pair is used After connecting the wires for RS485 operation make sure the slide switch on the main board to the camera head is positioned toward the LEDs default CAUTION Bosch recommends that multiple RS485 connections be arrang...

Страница 73: ... Optic Module with an RS232 RS422 Controller An AutoDome with a fiber optic module is prewired to operate with Biphase signals only This section describes the procedures necessary to control a VG5 series AutoDome fitted with a fiber optic kit using an RS232 controller or a Pelco RS422 controller To control a VG5 Series Autodome from an RS232 or from a Pelco RS422 controller you must run control wi...

Страница 74: ...rom the P106 connector 3 Remove the 100 Ω resistor across the C and C pins 4 Cut the five wires from the green Serial Communications wire mating connector Ensure that the insulation covers each wire to avoid wires from touching 5 Cut back the insulation on the blue ground wire and on the green RxD wire enough to be able to connect these wires back into the P106 connector 6 Connect the blue ground ...

Страница 75: ... Ensure that the VG5 AutoDome is set to receive RS232 commands Remove the bubble from the VG5 AutoDome housing Locate the protocol switch on the CPU board Ensure that the protocol switch is in the left position for RS232 operation Figure 5 9 Position of CPU Switch for RS232 Operation 11 Return the bubble to the AutoDome housing 12 Return power to the power supply box 1 Switch Location 2 LEDs 3 Mov...

Страница 76: ... how the alarm is configured a short or a break in the alarm s circuit can trigger the tamper signal 6 2 Configuring Supervised Alarms inputs 1 and 2 To configure Alarm 1 or 2 pin 5 or 6 for supervision you must install a 2 2 K end of line resistor in the circuit Then you program the alarms through the AutoDome main menu to either Normally Open Supervised N O S or Normally Closed Supervised N C S ...

Страница 77: ...stor in the alarm circuit 2 Connect the alarm wires to input 1 or 2 pin 5 or 6 and to the ground pin 7 at the AutoDome Figure 6 2 N C S Normally Closed Supervised Connections 3 From the AutoDome main menu select Alarm Setup Inputs Setup and set Alarm Input to N C S See the table below for contact and condition details AutoDome Programmed N O S Contact Alarm Condition Open Normal Closed Alarm Cut o...

Страница 78: ...nu select Alarm Setup Inputs Setup and set Alarm Input to N O See the table below for contact and condition details 6 3 2 Configuring a Normally Closed Non supervised Alarm 1 Connect the alarm to the appropriate input 1 through 7 and ground at the AutoDome Figure 6 4 N C Normally Closed Non supervised Connections 2 From the AutoDome main menu select Alarm Setup Inputs Setup and set Alarm Input to ...

Страница 79: ...a maximum voltage rating of 2 A 30 DC 1 Connect the appropriate stripped wire to the AutoDome COM connector 2 Connect the appropriate stripped wire to the N O or N C connector depending on your requirement 6 4 2 Configuring an Open Collector Output Outputs 1 2 and 3 are open collector types These outputs must be connected to a positive voltage between 5 and 32 V to complete the circuit with a maxi...

Страница 80: ...wing procedures and comply with all the warnings listed below 7 2 1 Cleaning the Bubble Interior The extremely soft interior surface should not be cleaned by rubbing or dusting with a cloth Use clean dry compressed air preferably from a spray can to remove any dust from the interior surface To remove the bubble from a pendant housing 1 Using both hands apply a firm counterclockwise looking up at t...

Страница 81: ...elow for an illustration Figure 7 2 Bubble Release Screw 7 2 2 Cleaning the Bubble Exterior The exterior of the bubble is hard coated for extra protection If cleaning becomes necessary only use cleaning solutions and cloths suitable for cleaning safety glass lenses Dry the bubble thoroughly with a dry nonabrasive cloth to prevent water spots Never scrub the bubble with any abrasive material or cle...

Страница 82: ...ffective distance that the AutoTracker can track an individual Bosch recommends a minimum camera height of 3 6 m 12 ft It is also important to note that the AutoDome will not tilt above the horizon when tracking The graph below shows the maximum tracking distance for an AutoDome with a specific camera installed at various heights Figure 1 1 Maximum AutoTracker distance for a camera at a certain he...

Страница 83: ...low of people to move across the camera s field of view Avoid motion that moves directly towards the camera Avoid locations that attract large numbers of people such as retail stores or intersections A 4 Unwanted Motion Use the Virtual Masking feature refer to the VG5 Series AutoDome User s Manual to mask unwanted motion from trees or cars Bosch recommends that you draw the virtual mask 10 larger ...

Страница 84: ...handling 80 release aperture 63 81 C cable compensation 67 cable standards 67 cables copper 67 fiber optic 69 camera height 82 coaxial cable 67 communication protocol RS232 71 control data I O plug 18 copper wire 67 corner installation 16 27 corner plate 16 cover door 39 D daisy chaining 18 70 dome bubble 63 dome cap 48 drywall ceiling 59 E Ethernet 61 F fiber optic 69 multimode 69 single mode 69 ...

Страница 85: ...r pendant arm corner or mast mount 14 wiring for pendant arm corner or mast mount 26 Pre Comp 67 preparing drywall ceiling 59 suspension ceiling 59 protocol RJ45 61 R relay 79 relay connectors 19 RJ45 61 roof parapet or pipe mount 36 45 cover door 39 dome cap 48 fiber optic model 56 parts 36 power supply box location 37 wall bracket 46 wall mount bracket 45 routing wires for in ceiling mount 60 fo...

Страница 86: ...86 en Index AutoDome 600 Series Analog PTZ Camera F 01U 265 793 2 0 2012 02 Installation Manual Bosch Security Systems Inc ...

Страница 87: ......

Страница 88: ... RVFK 6HFXULW 6 VWHPV QF HPSVWHDG 5RDG DQFDVWHU 3 86 ZZZ ERVFKVHFXULW FRP RVFK 6HFXULW 6 VWHPV QF 8 RVFK 6LFKHUKHLWVV VWHPH PE 5REHUW RVFK 5LQJ UDVEUXQQ HUPDQ ...

Отзывы: