Figure 5.1: Location of feed through wiring holes.
2.
Screw the two (2) 3/8-in. NPT fittings into the foot of the housing.
3.
Pull the cabling through the fittings into the housing. Tighten the fitting to 4.0 N m to
4.5 N m (35 in.-lb to 40 in.-lb). This torque rating is approximately 1 to 1.5 turns past the
point where the fitting starts to grip the wire. Failure to do this will result in water
damage to all electronic parts.
4.
Attach the foot to the top bracket of the mount.
5.
Ensure that the holes in the rear cap are covered with the rubber plugs provided. Push in
until flush and then release.
Power Connections
Power into the housings is to be supplied using type UL Standard SJ cord (or better)
acceptable for outdoor use. Installation must conform to NEC 400-4 CEC rule 4-010 and be
marked with OUTDOOR, W, or W-A. For 24 volt cameras, use the recommended maximum
cable lengths chart for selecting the proper wire size.
Wire size mm²
Wire size AWG
Distance m (ft)
0.5
20
27 (90)
1
18
42 (140)
1.5
16
67 (220)
2.5
14
108 (355)
4
12
172 (565)
Table 5.1: Recommended maximum cable lengths for housings equipped with 24 volt cameras, heaters, and
blowers
Wire sizes larger than 2.5 mm² (14 AWG) require a splice to accommodate the terminal block.
1.
If using the feed-through option, ignore this step. Install one of the large ½-in. NPT
fittings into one of the holes in the rear cap.
2.
Route the power cable through the fitting in the rear cap or through one of the feed-
through fittings in the foot.
5.1.4
20
en | Connection - Most Models
UHI/UHO Series Camera Housing
2014.05 | 4.0 | F.01U.167.418