Important Notices
Accessories - Do not place this unit on an unstable stand, tripod, bracket, or mount. The unit
may fall, causing serious injury to persons and/or severe damage to the unit. Use only with the
cart, stand, tripod, bracket, or table specified by the manufacturer. When a cart is used,
exercise caution and care when moving the cart/apparatus combination to avoid tipping it
over, which could result in injury. Quick stops, excessive force, or uneven surfaces may cause
the cart/unit combination to overturn. Mount the unit in line with the manufacturer's
instructions.
All-pole power switch - Incorporate an all-pole power switch, with a contact separation of at
least 3 mm in each pole, into the electrical installation of the building. If it is needed to open
the housing for servicing and/or other activities, use this all-pole switch as the main
disconnect device for switching off the voltage to the unit.
Camera grounding - When mounting the camera in potentially damp environments, ensure the
system is grounded through the metal housing of the unit (see section: Connecting the
Power).
Camera signal - Protect the cable with a primary protector if the camera signal is over 140
feet, in accordance with NEC800 (CEC Section 60).
Coax grounding:
–
Ground the cable system if connecting an outside cable system to the unit.
–
Connect outdoor equipment to the unit's inputs only after this unit has had its grounding
plug connected to a grounded outlet or its ground terminal is properly connected to a
ground source.
–
Disconnect the unit's input connectors from outdoor equipment before disconnecting the
grounding plug or grounding terminal.
–
Follow proper safety precautions, such as grounding, for any outdoor device connected to
this unit.
U.S.A. models only - Section 810 of the National Electrical Code, ANSI/NFPA No. 70, provides
information regarding proper grounding of the mount and supporting structure, grounding of
the coax to a discharge unit, size of grounding conductors, location of discharge unit,
connection to grounding electrodes, and requirements for the grounding electrode.
Your Bosch product was developed and manufactured with high-quality material and
components that can be recycled and reused. This symbol means that electronic and electrical
appliances that have reached the end of their service life must be collected and disposed of
separately from household waste material. Separate collecting systems are usually in place for
disused electronic and electrical products. Please dispose of these units at an environmentally
compatible recycling facility, in line with European Directive 2002/96/EC.
Environmental statement - Bosch has a strong commitment to the environment. This unit has
been designed to respect the environment as much as possible.
Electrostatic-sensitive device - Take proper CMOS/MOS-FET handling precautions to avoid
electrostatic discharge. NOTE: You must wear grounded wrist straps and observe proper ESD
safety precautions when handling the electrostatic-sensitive printed circuit boards.
Fuse rating - For security protection of the device, the branch circuit protection must be
secured with a maximum fuse rating of 16 A. This must be in accordance with NEC800 (CEC
Section 60).
1.3
6
en | Safety
UHI/UHO Series Camera Housing
2014.05 | 4.0 | F.01U.167.418
Operation Manual
Bosch Security Systems, Inc.