The terminal block accepts wire ranging from 0.5 mm² to 2.5 mm² (20 AWG to 14 AWG). When
using larger wire sizes, splice to a smaller size wire at the terminal block end. The splice may
need to be enclosed in a junction box if it does not pass through the fittings.
4
Connect the safety (earth) ground:
A terminal lug is provided for connecting the external safety (earth) ground to the grounding
post on the PCB bracket assembly.
!
Caution!
For compliance with safety regulations, the external ground wire must always be connected
to the main ground post.
–
To attach the external safety ground wire, remove the nut, the washers, and the external
ground wire lug from the ground post.
–
Strip and crimp the external ground wire into the lug.
–
Reattach the ground connections in the order shown in the figure below.
Figure 5.2: Safety grounding
1
Nut
2
Lock washer
3
Flat washer
4
External ground lug
5
External ground post
Notice!
Install the external ground in accordance with the NEC/CEC requirements.
UHI/UHO Series Camera Housing
Connection - Most Models | en
21
Bosch Security Systems, Inc.
Operation Manual
2014.05 | 4.0 | F.01U.167.418