4
Pull any excess wire out of the housing and tighten the fitting to 8.5 N m to 9.0 N m
(75 in.-lb to 80 in.-lb). This torque rating is approximately one to one and a half turns past
the point where the fitting starts to grip the wire.
Caution!
Always securely tighten all fittings to ensure a liquid-tight seal. Failure to do so could allow
water to enter the housing and to damage the camera and lens. If a sealant is used, ensure
that it is a neutral cure type. Sealants that release acetic acid may harm camera electronics.
Use of drip loops is recommended on the wiring outside of the rear end cap.
1.
Connect the supply power wires to the terminal block. See the figure below. Strip no less
than 6 mm (0.25 in.) and no more than 8 mm (0.31 in.) of insulation away from the wire.
Ensure not to nick the wires.
2.
Cut the power cord on 120 VAC and 230 VAC camera models; leave enough cable to allow
connection to the terminal block. Strip no less than 6 mm (0.25 in.) and no more than
8 mm (0.31 in.) of insulation away from the wire. Ensure not to nick the wires. Connect
these wires to the connectors provided on the terminal block.