5
Commissioning and Parameterization
5.1
Step 5: General Commissioning and Parameterization of
the Drive
Note:
By starting the command "PL", the drive should be brought to
a defined initial status.
See also Functional Description "Load basic parameters"
1. In order that basic parameters can be loaded you have to switch drive
controller to parameter mode. This can be done either directly via icon
(PM) in toolbar or by right-clicking "Start parameterization level 1".
Control panel display changes to "PM".
DB000216v01_en.tif
Fig. 5-1:
Switching to parameterization level 1