Error Message
Error Message
Error Message
Error Message
Description
Description
Description
Description
NO PREWET SENSOR OUTPUT
The controller is not receiving a signal from the
pre-wetting flow meter.
NO GATE SENSOR OUTPUT
The controller is not receiving a signal from the
Gate Location sensor.
16.3 Error Time Delay
The time delay before the error message is activated can be set here. Setting a
delay will prevent error messages from being activated as a result of temporary
faults.
Insert the programming key, select “ERROR CONFIG” and select “OPERATION”. The
screen to the left will appear.
Use the Down navigation button to move the cursor to the desired error function
and press the Enter button. The screen to the left will appear.
•
Use the Down navigation button to move the cursor to “05 Seconds delay” and
press the Enter button.
•
Using the Left or Right navigation button, move to number to be changed.
•
Using the Up or Down navigation button, change the number as required.
•
Once all the numbers have been changed, press the Enter button.
•
Repeat the same for each error function.
16.4 Error Action
This option allows you to select the desired action the controller is to activate after
the error message is acknowledged by the operator.
Insert the programming key, select “ERROR CONFIG”, and select “OPERATION”. The
screen to the left will appear.