8 Material Configuration
8.1 Naming the Material
Insert the programming key, select “MATERIAL SETUP” and select “SOLID 1”. The
screen to the left will appear.
•
Using the Left or Right navigation button move to the letter or number to be
added or changed.
•
Using the Up or Down navigation button, change the letter or number as
required.
•
Once all the letters or numbers have been added or changed press the Enter
button.
8.2 Programming the Material Spread Rates
Insert the programming key, select “MATERIAL SETUP” and select desired solid. The
screen the left will appear.
•
Use the Down navigation button to move the cursor to the desired line to be
changed and press the Enter button.
•
Using the Left or Right navigation button move to the letter or number to be
added or changed.
•
Using the Up or Down navigation button, change the letter or number as
required.
•
Once all the letters or numbers have been added or changed press the Enter
button.
8.3 Calibration Procedure
Insert the programming key, select “MATERIAL SETUP” and select the desired solid.
The screen to the left will appear.
8.3.1 Gate Setting for C
8.3.1 Gate Setting for C
8.3.1 Gate Setting for C
8.3.1 Gate Setting for Calibration
alibration
alibration
alibration
Adjust gate to a position for the material.
Enter the GATE setting to be used during the calibration procedure.
If gate is in manual
manual
manual
manual mode:
1.
Use the Down navigation button to move the cursor to “GATE” and press the
Enter button.
2.
Using the Left or Right navigation button, move to the number to be changed.
3.
Using the Up or Down navigation button, change the number as required.
4.
Once all the numbers have been changed, press the Enter button.