Disassembly and replacement | Automax 100 | Extension module TS-AC E2-M3-1X
79/94
Bosch Rexroth AG | 05.2021 | DOK-SUPPL*-TS-AC E2-M3-ITRS-EN-P
Disassembly and replacement
DANGER
Compromising of the training system, individual components or other assets. Risk
for safe operation of the training system!
Risk of injury or death for operator or third
Chapter „
” as of page [
] in these operating instructions must
always be observed!
CAUTION
Risk of injury due to improper handling!
Physical injury due to crushing, shearing, cutting, pushing or improper handling!
Observe the general setup and safety instructions for handling and assembly
Prevent entrapment and crushing by taking suitable precautions
If necessary, use suitable protective equipment (for example safety shoes, protective
gloves ...)
CAUTION
Material damage due to improper handling!
Proper handling can lead to damage or device defect!
Disconnect the base module from the supply voltage before carrying out any extension
or conversion work
Make sure that the polarity of the connections is correct. Observe color coding!
Carry out extension and conversion work without mechanical force
NOTICE
Do not touch electrostatically sensitive components or connection points!
Property damage
Observe the ESD protection measures
Do not touch connection points
The conversion is basically carried out in the reverse order to the extension of the system.
The following example describes the conversion based on the configuration of the base
module with an extension module in slot 2.
ATTENTION! Modification work may only be carried out when the equipment is de-
energized.
Step 1
Disconnect the three safety lab plugs of the extension module from the safety lab sockets of
the base module. Plug them into the safety lab jacks of the extension module (park
position).