20/94 About this product | Automax 100 | Extension module TS-AC E2-M3-1X
Bosch Rexroth AG | 05.2021 | DOK-SUPPL*-TS-AC E2-M3-ITRS-EN-P
Safety plug (GND)
Safety plug (+24 V/U
LS
)
Safety plug (+24 V/U
A
)
Safety socket (GND)
Safety socket (+24 V/U
LS
)
Safety socket (+24 V/U
A
)
Parking position
Voltage supply of the extension module
For voltage supply, the three safety plugs (
) must be connected to the respective
safety sockets in the basic module. To prevent confusion, the plugs and sockets are color-
coded. This means, the colored plugs must be connected to the sockets with the same
color.
If an additional extension module is attached, 3 color-coded safety sockets (
) are
available for supply connection. For this, the individual safety plugs and safety sockets are
internally bridged.
For safekeeping of the extension module, the plugs are connected to the sockets, see „
“ Parking position (
) as of page [
].
The hanging connection cables can be pushed back into the housing.
Use of U
A
voltage
The components installed in this expansion module are supplied with 24 V/U
LS
.
Nevertheless, it is recommended to connect all three safety measuring plugs to a
corresponding base module for the voltage supply of this expansion module. See
“ as of page [
]. This ensures that the U
A
voltage is available
on the -3XG1 and -4XG1 connectors on pin 11 of the M12 system connectors. Thus,
external applications can be supplied with a U
A
voltage.