RE 91485-01-B/2021-11-18, Bosch Rexroth AG
Installation |
A10FZO/G, A10VZO/G
49
/72
L
L
L
1
B
B
A
A
NG3 … 18
NG21 … 63
Abb� 29: Port overview A10FZG, SAE flange ports (port plate 02)
L
L
1
L
1
X
X
L
2
B
B
A
Abb� 30: Port overview A10VZG, DG control, SAE flange ports (port plate 02)
Tabelle 27: Ports A10FZG
Ports
1)
p
max
[bar]
2)
State
3)
A, B
Working port (high-pressure series)
350
O
L
Drain port
2
O
4)
L
1
Drain port (only NG21 to 63)
2
X
4)
Tabelle 28: Ports A10VZG
Ports
1)
p
max
[bar]
2)
State
3)
A, B
Working port (high-pressure series)
350
O
L
Drain port
4
O
4)
L
1
Drain port
4
X
4)
L
2
Drain port (only NG18 to 63)
4
X
4)
X
Pilot pressure
250
O
1)
The measuring system and thread size can be found in the installation drawing.
2)
Depending on the application, momentary pressure peaks can occur. Keep this in mind when
selecting measuring devices and fittings.
3)
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
4)
Dependent on the installation position,
L
,
L
1
or
L
2
must be connected
(see chapter 7.3 "Installation position A10FZG, A10VZG" on page 38).
Port overview
A10FZG
Port overview
A10VZG