The following tightening torques apply:
• Fittings:
Observe the manufacturer's specifications regarding the tightening torques of the
fittings used.
• Female threads in the axial piston unit:
The max. permissible tightening torques
M
G max
are the maximum values for the
female threads and should not be exceeded. For values, see Tabelle 29.
• Threaded plugs:
For the metallic threaded plugs supplied with the axial piston unit, the required
tightening torques of threaded plugs
M
V
apply. For values, see Tabelle 29.
• Mounting bolts:
For mounting bolts with metric ISO threads according to DIN 13 and/or
ASME B1.1 threads, we recommend checking the tightening torque in individual
cases in accordance with VDI 2230.
In addition to the ports specified in Tabelle 25 to Tabelle 28
"Ports A10FZO, A10VZO, A10FZG and A10VZG" on page 48 and 49,
axial piston units may have openings that are also closed with a threaded plug.
These plugs must not be opened on the customer side! If you have opened the
threaded plug accidentally, please contact your local contact person to ensure
safe re-closing of the plug. You can find the address at
https://addresses.boschrexroth.com
Tightening torques