Transport and storage 39/64
RE 50129-B/02.19, Accumulator shut-off block type ABZSS, 0532VAW,
Bosch Rexroth AG
For storage of the accumulator shut-off block, the following storage conditions must be
complied with:
Table 7: Storage conditions
Denomination
Area
Temperature range
10-25 °C
Relative air humidity (no condensation)
max. 65%
UV protection
100%
Condensation
none
Additional ozone formation near the storage location.
none
No special preservation necessary.
Contact Bosch Rexroth for the preservation and later commissioning of the
accumulator shut-off block if the accumulator shut-off block must be stored for a
period of more than three months.
6.4 Painting the accumulator shut-off block
NOTICE
Restriction of functionality or overheating of the accumulator shut-off block due
to coating!
Damage to property!
▶
Close the hydraulic connections completely before the paint application.
▶
Protect the surface of the solenoid coils as well as fixing holes and surfaces
from paint application.
▶
Cover the name plate of the accumulator shut-off block as well as the name
plates of the valves in such a way that they remain readable after painting.
▶
Cover the connectors of the electrical connections with protective foil and make
sure not to cause any damage to the connector.
▶
When removing the paint protection and the covers make sure that no paint
chips or other foreign particles enter the accumulator shut-off block.
Storage conditions
Storage up to 3 months
Storage longer than 3
months