Product information 29/64
RE 50129-B/02.19, Accumulator shut-off block type ABZSS, 0532VAW,
Bosch Rexroth AG
5.3.2 Hydraulic connections types 0532VAW20 and 0532VAW32
0532VAW20_4
0532VAW32_4
1
1
2
2
3
3
4
4
5
5
1
Measuring port "M1"
2
Measuring port "M2"
3
Pump port "P"
4
Tank port "T"
5
Accumulator port "S"
Measuring port for pressure monitoring (see circuit diagram).
Measuring port for pressure monitoring (see circuit diagram).
Pump port for filling the hydraulic accumulator with oil.
Via the tank port, the oil is returned to the tank on manual or electrical relief of the
hydraulic accumulator (discharge line) in case of inadmissible overpressure.
Via the accumulator port, the hydraulic accumulator is connected to the accumulator
shut-off block.
Fig. 9: Hydraulic connections types 0532VAW20 and 0532VAW32
(illustrated without shut-off cock)
Measuring port "M1" (1)
Measuring port "M2" (2)
Pump port "P" (3)
Tank port "T" (4)
Accumulator port "S" (5)