Assembly 45/64
RE 50129-B/02.19, Accumulator shut-off block type ABZSS, 0532VAW,
Bosch Rexroth AG
▶
Remove any protective plugs.
▶
Check the hydraulic connections and lines for cleanliness.
▶
Make sure that the line connections contain the intended seals.
▶
If necessary, secure O-rings against slipping using installation grease.
▶
Connect the lines for pump port "P" / pump ports "P1" and "P2" and the tank
port "T" according to the specifications of the system/machine manufacturer.
– Observe the tightening torques of the fitting manufacturer.
▶
Connect the hydraulic accumulator at the accumulator port "S" to the
accumulator shut-off block.
▶
Connect the measuring ports M1 and M2 to a pressure gauge.
The hydraulic supply of the accumulator shut-off block is now established.
7.5.4 Electrically connecting the accumulator shut-off block
NOTICE
Incorrectly connected electrical components!
Damage to property!
▶
Connect the electric components according to the electric circuit diagram and
the pin assignment.
▶
Make sure that electrical components are connected by a specialized electrician.
For electrical connection of the accumulator shut-off block, the following work steps
have to be performed:
▶
Before the assembly, de-energize the electrical control system.
▶
Familiarize with the position of the electrical connections.
– Also observe chapter 5.4 "Electrical connections".
▶
Regarding the electric wiring at the control block accumulator shut-off block,
observe the data sheets of the electric components.
▶
Check the electrical connections for cleanliness.
▶
Connect the accumulator shut-off block according to system or machine
manufacturer specifications.
The power supply of the accumulator shut-off block is connected.