1 689 988 262
2017-12-26
|
Robert Bosch GmbH
70 | EPS 625 | Technical data
en
Property
Unit
Value
Noise
Workplace emission sound pressure level L
pa
with drive motor
running at a speed of 4000 min-1 and without injection pump
dB
81
Auxiliary power supply
Adjustable DC power supply for start / stop magnet
V
12 /24
A
7
Permissible ambient temperature ranges
Maximum ambient temperature
°C
40
Operating range
°C
5 to 40
Accuracy
°C
10 to 30
Storage temperature
°C
-25 to 60
Miscellaneous
Average time taken to heat test oil from 25
°C to 45 °C
minutes
approximately 20 mins
Minimum recommended quantity of test oil in the test oil tank
lts
30
9.2
Bench Layout
2320
1715 (max:1790)
354
2910
610
20
20
20
10
24
7.5
4.1
15⁰
180⁰
A
B
458868_100Nkv
230V AC 3A
673
1346
C
C
Fig. 26: Bench layout
(All dimensions in mm)
A Gap between flywheel and pointer
B Gap between pointer and front panel
C Maximum position with control cabinet door open
Содержание EPS 625
Страница 412: ......