1 689 988 262
2017-12-26
|
Robert Bosch GmbH
Initial start-up | EPS 625 | 57
en
6.
Fill about 50 lts of fresh test oil to the test oil tank.
i
Any of the following brands of ISO 4113 test oil can
be used:
Test oil brand
Manufacturer
SHELL Calibration Fluid S 9365
Shell International
SHELL V-OL 1404
Shell Germany
SHELL Normalfluid B.R
Shell France
VISCOR Calibration Fluid 1487 AW-2
Rock Vallery
CASTROL Fluido para Calibracao 4113 Castrol Brazil
ESSO EGL 270 147
ESSO AG
BENZ UCF-1 Calibration Fluid
Benz Oil
i
During the test run, it is necessary to bleed air pock-
ets in the pipeline and top up the oil level in the test
oil tank.
7.
Route the pneumatic hose (
Ø6 mm
) into the ma-
chine from the bottom through the opening for the
water connection.
8.
Connect the pneumatic hose with 6 bar pressure
(maximum) to the pneumatic filter (Fig. 9, Pos. 1).
9.
Close the bottom rear panel.
4.4.5
Connection for cooling water
i
Following components must be installed in the inlet
line:
$
Pressure reducing valve with pressure gauge set
to 200 Kpa
$
Protective filter
$
Shut-off valve
1.
Connect the cooling water connection to the water
supply.
2.
Route the flexible water lines (inlet and return) to
the heat exchanger using suitable clamps.
3.
Ensure that the connections are leak-proof.
i
The cooling water supply valve to the bench must be
closed when EPS 625 is not in use.
4.4.6
Checking pressure gauges
¶
Observe the pointer of the pressure gauge.
The pointer should read "0".
459897_136Nkv
1
Fig. 21: Equalizing pressure inside the gauge
1
Rubber cap
i
If the pointer does not point zero, open the rubber
cap (Fig. 21, Pos. 1) to equalize the pressure inside
the gauge to the atmospheric pressure. Once the
pressure is equalized, close the cap.
4.4.7
Connecting personal computer (PC)
i
Heed the system prerequisites for the PC (refer to
Section 3.2.1).
1.
Connect the PC accessories (monitor, keypad,
mouse, etc.) to the PC.
2.
Make the electrical connection for the PC and PC
accessories.
3.
Connect the PC by way of the USB connecting cable
F 002 DG1 9C7 (special accessory) to the USB port
of the EPS 625 (Fig. 1, Pos. 9).
i
Make exclusive use of the USB connecting cables
specified by Bosch.
4.4.8
Installing EP-Software
i
Details of EP software installation can be
found in the "EP software" program description
(1 689 989 099).