DIVAR IP all-in-one 7000 3U
System overview | en
15
Bosch Security Systems B.V.
Installation manual
2021.10 | V02 | DOC
7
VGA display output (disabled)
8
DVI-I port
9
2 Display ports
10
Audio Line out
11
Audio MIC in
3.3
Control panel elements
The control panel located on the front of the chassis features power buttons and status
monitoring LEDs.
Control panel buttons
Button
Description
Power
The power button is used to apply or remove power from the power supply to
the system.
Note:
Turning off system power with this button removes the main power,
but keeps standby power supplied to the system.
To remove all power, unplug the system before performing maintenance
tasks.
Reset
The reset button is used to reboot the system.
Control panel LEDs
The control panel LEDs provide status information about the system.
LED
Description
Power failure
This LED indicates that a power supply module has failed.
Information
This LED indicates the system status.
System status
Description
Continuously on and red
An overheat condition has occurred. (This
may be caused by cable congestion.)
Blinking red (1 Hz)
Fan failure: check for an inoperative fan.
Blinking red (0.25 Hz)
Power failure: check for an inoperative
power supply.
Solid blue
Local UID has been activated. Use this
function to locate the unit in a rack
environment.
Blinking blue (300 msec)
Remote UID has been activated. Use this
function to locate the unit from a remote
location.
This LED indicates network activity on GLAN2 when flashing.