9.3 General Data
9.3.1 System Environmental Conditions
Temperature range
Storage and transport: -20 to +70°C (-4 to +158°F)
Operational:
+5 to +45°C (+41 to 113°F)
Ambient humidity
Operational:
20% - 95% RH
Storage and transport: 0% - 99% RH
Air pressure:
600 mBar - 1100 mBar
Safety:
acc. to EN 60065 and acc. to
UL 60065
Resistance to shock,
vibration, bump
and transport:
acc. to IEC 60068, 5G accelera-
tion
EMC emission:
acc. to EN 55103-1 and FCC
rules (part 15), class A
EMC immunity:
acc. to EN 55103-2
EMC approvals:
affixed with the CE mark
Mains harmonics:
EN 61000-3-2 and EN61000-3-3
Transport:
AV18-Q0681
9.3.2Equipment Range
Control and power
supply unit:
CCS-CU
CCS-CUD (with Digital Acoustic
Feedback Suppression)
CCS-CUR (with recording)
CCS-CURD (with recording and
Digital Acoustic Feedback Sup-
pression)
19" rack mounting set: LBB 3311/00
Bracket for flush
mounting:
can be made locally according to
the illustration in 9 Appendix
Delegate unit(s):
LBB 3330/00
LBB 3330/50
(with long microphone)
Chairman unit(s) :
LBB 3331/00
LBB 3331/50
(with long microphone)
Installation cable with
connectors
LBB 3316/00 (100 m)
Extension cables :
LBB 3316/05 (5m)
LBB 3316/10 (10m)
Cable locking clamps :LBB 4117/00 (set of 25 pieces)
Transport suitcase for
10 delegate/chairman
units with standard
microphone:
LBB 3312/00
Transport suitcase for
one CU, 6 delegate/
chairman units with
standard and/or long
microphone and some
extension cables:
LBB 3312/10