Auto microphone switch-off function selectable on
the Control and Power Supply Unit
After approximately 30 sec. not speaking (sound level
below 64 dB SPL) the microphone is automatically
switched off
System limits
Number of delegate/chairman units connected to CU
Maximum in total:
50
Maximum per
trunk output:
25
Maximum trunk length
using CCS 800 Ultro
standard cabling:
100 m (328 ft)
9.1.2 Combined Units
Delegate microphones with transmission links to
delegate headphones and auxiliary outputs.
General
Frequency response:
125 Hz - 12.5 kHz tolerances
acc. to IEC 914 standard
Total harmonic distortion at overload
at nominal input
level (85 dB SPL):
< 0.5%
at max. input
level (110 dB SPL):
< 3%
9.2 Mechanical Data
9.2.1 Control and Power Supply Unit
Mounting:
free standing on a table top or
mounted in a 19" rack (requires
3HU (Height Units) with bracket
set LBB 3311/00). Information
about how to make the necessary
brackets for table flush mounting
is included.
Dimensions(HxWxD): 84 x 361 x 143 mm (with 5.5
mm feet)
3.4 x 14.2 x 5.6 in (with 0.22 in
feet).
Weight:
/00 version 1.5 kg (3.3 lb)
/10 version 1.7 kg (3.8 lb)
9.2.2Delegate/Chairman Units
Dimensions (w x d x h)
without mic.:
124 x 172 x 63 mm
(4.9 x 6.8 x 2.5 in)
Length of mic. from
mounting surface:
/00 version, 313 mm (12.3 in)
/50 version, 488 mm (19.2 in)
Weight:
0.9 kg (2.0 lb)