background image

SCALE IS 5 DECIBELS PER DIVISION

Polar Pattern

200 Hz

LEGEND

5 kHz

1 kHz

8 kHz

240

180

210

270

300

330

0

150

120

90

30

60

12" or more on axis

100

50

200

LEGEND

Roll-off

10k

5k

1k

500

2k

20k

Frequency in Hertz

Frequency Response

Response in dB

10 dB

• Ideal for sax, toms, brass and percussion

• Excels in high-SPL applications

• Perfect for active stage performances

• Extended frequency response captures subtle nuances of the 

performance

• UniMount

®

clip permits accurate positioning, provides shock 

resistance and protects element

• Corrosion-resistant contacts from gold-plated XLRM-type 

connector

• Cardioid polar pattern reduces pickup of sounds from the sides 

and rear, improving isolation of desired sound source

The PRO 35ax is intended for use in professional applications
where remote power is available. It requires 11V to 52V DC 
phantom power, which may be provided by a mixer or console, or
by a separate, in-line source such as the Audio-Technica AT8801
single-channel or CP8506 four-channel phantom power supplies.

An integral 80 Hz high-pass filter provides easy switching from a flat
frequency response to a low-end roll-off. The roll-off position
reduces the pickup of low-frequency ambient noise (such as traffic,
air-handling systems, etc.), room reverberation and mechanically
coupled vibrations.

Output from the power module’s XLRM-type connector is low
impedance (Lo-Z) balanced. The signal appears across Pins 2 and
3; Pin 1 is ground (shield). Output phase is “Pin 2 hot” – positive
acoustic pressure produces positive voltage at Pin 2.

To avoid phase cancellation and poor sound, all mic cables must be
wired consistently: Pin 1-to-Pin 1, etc.

Avoid leaving the microphone in the open sun or in areas where
temperatures exceed 110° F (43° C) for extended periods.
Extremely high humidity should also be avoided.

PRO 35ax SPECIFICATIONS

ELEMENT

Fixed-charge back plate 
permanently polarized  condenser

POLAR PATTERN

Cardioid

FREQUENCY RESPONSE

50-15,000 Hz

LOW FREQUENCY ROLL-OFF

80 Hz, 12 dB/octave

OPEN CIRCUIT SENSITIVITY 

–45 dB (5.6 mV) re 1V at 1 Pa*

IMPEDANCE 

250 ohms  

MAXIMUM INPUT SOUND LEVEL 

145 dB SPL, 1 kHz at 1% THD

DYNAMIC RANGE

(typical)

115 dB, 1 kHz at Max SPL

SIGNAL-TO-NOISE RATIO

1

64 dB,1 kHz at 1 Pa*

PHANTOM POWER REQUIREMENTS 

11-52V DC, 4 mA typical

SWITCH 

Flat, roll-off

WEIGHT

(less cable and accessories)

MICROPHONE

0.3 oz (8 g)

POWER MODULE 

2.0 oz (56 g)

DIMENSIONS

MICROPHONE

0.98" (25.0 mm) long,
0.40" (10.2 mm) diameter

POWER MODULE 

3.86" (98.0 mm) long,
0.74" (18.9 mm) diameter

OUTPUT CONNECTOR 

Integral 3-pin XLRM-type

(power module)

CABLE 

Integral 6' (1.8 m) permanently 
attached between microphone and 
power module 

ACCESSORIES FURNISHED 

AT8418 UniMount

®

microphone 

instrument mount; AT8536 power 
module; soft protective pouch

†In the interest of standards development, A.T.U.S. offers full details on its test 

methods to other industry professionals on request.

*1 Pascal = 10 dynes /cm

2

= 10 microbars = 94 dB SPL

1

Typical, A-weighted, using Audio Precision System One.

Specifications are subject to change without notice.

Audio-Technica U.S., Inc., 

1221 Commerce Drive, Stow, Ohio 44224

Audio-Technica Limited,

Old Lane, Leeds LS11 8AG England

www.audio-technica.com

P51679-EN     ©2004  Audio-Technica U.S., Inc.    Printed in Japan