APPENDIX A
Power Wiring Guide
AutoDome Power Wiring Connections
Refer to the following diagram to ensure proper wiring of the
EnviroDome. If using the ENV-PSU for power, use the
THREE WIRE POWER distances identified below.
WARNING:
Failure to correctly wire the power to the
EnviroDome could result in malfunction of the heater.
NOTE:
If using the ENV-PSU with the AutoTracker option, the
RS-232 connections (RXD, TXD, GND) must be used. The
maximum distance for RS-232 communications is 50 feet.
Appendix A
EN
© 2003 Bosch Security Systems
Page 19 of 24
TWO WIRE POWER
C–
24 VAC
THREE WIRE POWER (EnviroDome)
FOUR WIRE POWER (EnviroDome)
Transformer Output
24 VAC @
50 VA
Add Wire
Jumper
Dome Connector
Dome Connector
Dome Connector
Transformer
Output
24 VAC @
30 VA
Transformer
Output
24 VAC @
20 VA
Transformer
Output
24 VAC @
30 VA
Transformer
Output
24 VAC @
20 VA
AWG Max. Distance - ft (m)
18
90 ft (27.43)
16
140 ft (42.67)
14
225 ft (68.58)
C+ GND RXD TXD GND
H*
C–
C+ GND RXD TXD GND
H*
24 VAC
24 VAC
C–
C+ GND RXD TXD GND
H*
Neutral
Hot
Hot
Hot
Hot
Hot
Neutral
Neutral
Neutral
F
OR
EnviroDome
AWG Max. Distance - ft (m)
18
225 ft (68.58)
16
358 ft (109.12)
14
570 ft (173.74)
F
OR
I
NDOOR
U
NITS
O
NLY
(UNITS NOT REQUIRING HEATERS):
AWG Max. Distance - ft (m)
18
112 ft (34.14)
16
180 ft (57.91)
14
285 ft (86.87)
AWG Max. Distance - ft (m)
18
150 ft (45.72)
16
239 ft (72.85)
14
380 ft (115.82)
24 VAC @ 20 VA
F
OR
EnviroDome
F
OR
EnviroDome
*Heater connection for EnviroDome only.
Figure 5
Содержание AutoDome