5.4.2.4. If the Alarm inputs or contact output are being used,
connect the appropriate stripped wires to the 8-pin Alarm con-
nector per FIGURE 4.
Figure 4
NOTE:
The Alarm inputs must be connected to a Normally
Open dry contact. To activate the Alarm input, the contact
must close between the appropriate Alarm Input and the Alarm
Ground, pin #8. For example, to activate Alarm Input #1, the
relay must close between pins 7 & 8, (see FIGURE 4).
The maximum distances between the dry contact and the
AutoDome are as follows:
20 AWG
19,000 feet
22 AWG
12,000 feet
5.4.3
Align the Dome
5.4.3.1. Lift the AutoDome into the Dome Cap and align the
notch on the AutoDome with the notch on the side of the
Dome Cap, (as shown in PHOTO 5I).
5.4.3.2. Twist the dome counterclockwise until it stops turn-
ing (approximately a 90° rotation).
Photo 5I
5.4.3.3. Tighten the two slotted locking screws at the top of
the dome, as shown in PHOTO 5J.
Photo 5J
Installation
EN
© 2003 Bosch Security Systems
Page 18 of 24
GND A1
A2
A3
A4
NC COM NO
8
7
6
5
4
3
2
1
ALARM CONNECTOR
ALARM GROUND
ALARM INPUT #1
ALARM INPUT #2
ALARM INPUT #3
NORMALLY OPEN
RETAINING SCREW
RELAY COMMON
NORMALLY CLOSED
ALARM INPUT #4
Align Notches
Rotate
Содержание AutoDome