11
In th
e
following cas
e
s
,
you
m
ust stop th
e
applianc
e
i
mme
diat
e
ly and contact th
e
aft
e
r-sal
e
s s
e
rvic
e
:
− If you hav
e
accid
e
ntally vacuu
me
d up so
me
liquid
or liquid has
e
nt
e
r
e
d th
e
insid
e
of th
e
applianc
e
;
− If th
e
applianc
e
has b
ee
n dropp
e
d and da
m
ag
e
d.
Prot
e
ct th
e
vacuu
m
cl
e
an
e
r fro
m
outsid
e
w
e
ath
e
r con-
ditions
,
m
oistur
e
and sourc
e
s of h
e
at.
Do not pour fla
mm
abl
e
substanc
e
s or substanc
e
s con-
taining alcohol onto th
e
filt
e
rs (
m
otor prot
e
ction filt
e
r
,
e
xhaust filt
e
r
,
e
tc.).
Th
e
vacuu
m
cl
e
an
e
r is not suitabl
e
for us
e
on con-
struction sit
e
s. => Vacuu
m
ing up building rubbl
e
m
ay
da
m
ag
e
th
e
applianc
e
.
Switch off th
e
applianc
e
wh
e
n it is not in us
e
.
For saf
e
ty r
e
asons
,
th
e
applianc
e
is fitt
e
d with an ov
e
r-
h
e
ating prot
e
ction syst
em
to saf
e
guard th
e
batt
e
ry
and
m
otors. Th
e
applianc
e
will switch off auto
m
ati-
cally if it or th
e
batt
e
ry is too hot.
>
= Th
e
applianc
e
will n
ee
d around 30
m
inut
e
s to cool
down b
e
for
e
it can b
e
us
e
d again.
Th
e
packaging is d
e
sign
e
d to prot
e
ct th
e
vacuu
m
cl
e
an
e
r fro
m
b
e
ing da
m
ag
e
d during transportation.
W
e
th
e
r
e
for
e
r
e
co
mme
nd k
ee
ping th
e
packaging for
th
e
purpos
e
of futur
e
transportation.
Li
-
ion batterie
s
Re
ad all th
e
saf
e
ty infor
m
ation and instructions.
>
= Failur
e
to act in accordanc
e
with th
e
saf
e
ty
infor
m
ation and instructions
m
ay r
e
sult in
e
l
e
ctric
shock
,
fir
e
and/or s
e
rious injury.
K
ee
p all th
e
saf
e
ty infor
m
ation and instructions for
futur
e
r
e
f
e
r
e
nc
e
.
Prot
e
ct th
e
batt
e
ry fro
m
h
e
at sourc
e
s
,
for
e
xa
m
pl
e
avoiding long p
e
riods in th
e
sun and
e
xposur
e
to fir
e,
as w
e
ll as fro
m
wat
e
r and
m
oistur
e
.
>
=
R
isk of
e
xplosion.
Fu
me
s
m
ay b
e
r
e
l
e
as
e
d if th
e
batt
e
ry is da
m
ag
e
d or
us
e
d i
m
prop
e
rly.
C
irculat
e
fr
e
sh air
,
and s
ee
k
me
dical
assistanc
e
in th
e
e
v
e
nt of physical sy
m
pto
m
s arising
as a r
e
sult of
e
xposur
e
.
>
= Th
e
fu
me
s
m
ay irritat
e
th
e
airway.
If th
e
batt
e
ry is us
e
d incorr
e
ctly
,
liquid
m
ay l
e
ak out of
th
e
batt
e
ry. Avoid touching th
e
liquid. In th
e
e
v
e
nt of
accid
e
ntal contact
,
rins
e
th
e
aff
e
ct
e
d ar
e
a with wat
e
r.
If th
e
liquid co
me
s into contact with th
e
e
y
e
s
,
s
ee
k
me
dical assistanc
e
.
>
= If batt
e
ry liquid l
e
aks
,
it can irritat
e
or burn th
e
skin.
Tran
s
portation infor
m
ation
Th
e
Li-ion batt
e
ri
e
s in th
e
applianc
e
ar
e
subj
e
ct to th
e
r
e
quir
eme
nts of dang
e
rous goods l
e
gislation. Th
e
bat-
t
e
ri
e
s can b
e
transport
e
d by th
e
us
e
r by road without
any furth
e
r r
e
quir
eme
nts. In th
e
e
v
e
nt that th
e
y ar
e
shipp
e
d by a third party (
e
.g. transport
e
d by air or
fr
e
ight carri
e
r)
,
sp
e
cial r
e
quir
eme
nts r
e
garding packag-
ing and id
e
ntification
m
ust b
e
me
t. In this cas
e,
a dan-
g
e
rous goods
e
xp
e
rt
m
ust b
e
consult
e
d wh
e
n pr
e
paring
th
e
goods for dispatch.
Infor
m
ation on di
s
po
s
al
Vacuu
m
cl
e
an
e
rs
,
batt
e
ri
e
s
,
acc
e
ssori
e
s and packag-
ing should b
e
r
e
cycl
e
d in an
e
nviron
me
ntally fri
e
ndly
m
ann
e
r.
Do not dispos
e
of th
e
vacuu
m
cl
e
an
e
r or th
e
batt
e
ri
e
s in
th
e
hous
e
hold rubbish.
Packaging
Th
e
packaging is d
e
sign
e
d to prot
e
ct th
e
vacuu
m
cl
e
an
e
r fro
m
b
e
ing da
m
ag
e
d during transportation.
It is
m
ad
e
of
e
nviron
me
ntally fri
e
ndly
m
at
e
rials and
can b
e
r
e
cycl
e
d. Dispos
e
of packaging that is no
long
e
r r
e
quir
e
d at an appropriat
e
r
e
cycling point.
Old appliance
s
This applianc
e
contains r
e
charg
e
abl
e
lithiu
m
-ion
batt
e
ri
e
s. Th
e
applianc
e
m
ust th
e
r
e
for
e
only b
e
dispos
e
d of by an authoris
e
d aft
e
r-sal
e
s s
e
rvic
e
or
d
e
al
e
r.
Batterie
s
Pl
e
as
e
follow th
e
not
e
s on transport.
Int
e
grat
e
d batt
e
ri
e
s
m
ay only b
e
r
em
ov
e
d by sp
e
cial-
ist p
e
rsonn
e
l for th
e
purpos
e
of disposal. Op
e
ning
th
e
housing sh
e
ll
m
ay da
m
ag
e
th
e
vacuu
m
cl
e
an
e
r.
Only for qualifi
e
d prof
e
ssional:
To r
em
ov
e
th
e
batt
e
ry fro
m
th
e
vacuu
m
cl
e
an
e
r
,
pr
e
ss th
e
on/off switch (
Fig.
4
) until th
e
batt
e
ry is
fully discharg
e
d. Unscr
e
w th
e
scr
e
ws on th
e
housing
and tak
e
off th
e
housing sh
e
ll to r
em
ov
e
th
e
batt
e
ry.
To pr
e
v
e
nt a short circuit
,
disconn
e
ct th
e
batt
e
ry
conn
e
ctions individually on
e
aft
e
r th
e
oth
e
r and
th
e
n insulat
e
th
e
t
e
r
m
inals.
Ev
e
n in th
e
cas
e
of co
m
pl
e
t
e
discharg
e,
th
e
batt
e
ry
still contains a r
e
sidual capacity that
m
ay b
e
r
e
-
l
e
as
e
d in th
e
e
v
e
nt of a short circuit.
Содержание 4242005110728
Страница 2: ...2 1 2 19 8 3 4 6 5 7 9 10 11 12 15 16 18 17 14 13 20 ...
Страница 3: ...3 2 1 1 2 1 1 2 5 1 2 1 3 4 2 ...
Страница 4: ...4 Click 11 6 2 1 1 Click 2 1 10 9 8 7 Click ...
Страница 5: ...5 13 Click b 15 a b 14 a 12 1 13 16 b 24h c 16 a ...
Страница 6: ...6 17 17 1 2 Click ...
Страница 122: ...122 ...
Страница 123: ...123 ...