54
12-2 Format
12-2-1 Stream Mode
ID
Sign
Weight Data
Decision
1 2
3 4 5
6 7 8 9 10 11 12 13
<STX>
0
1
±
1
2
3
.
4
5
6
L
<ETX>
<STX> 0 1
±
1
2 3 . 4 5 6
O <ETX>
<STX> 0 1
±
1
2 3 . 4 5 6
H <ETX>
<STX>
0 1
±
1
2 3 4 5 6 .
H <ETX>
Warning : When there is no decimal point in display, decimal point is received at the end of weight data.
12-2-2 Command mode
1.
Command to request data
Current value is requested
.
Command example
ID
Command
1 2 3 4 5
<STX>
0
1
R
<ETX>
02
30 31 52 03
Response example
(ASCII)
ID
Sign
Weight data
Decision
1 2 3 4 5
6 7 8 9 10
11 12 13
<STX>
0
1
±
1
2
3
.
4
5
6
L
<ETX>
<STX> 0 1
±
1
2 3 . 4 5 6
O
<ETX>
<STX> 0 1
±
1
2 3 . 4 5 6
H
<ETX>
<STX>
0 1
±
1
2 3 4 5 6 .
H
<ETX>
Warning : When there is no decimal point in display, decimal point is received at the end of weight data.
Response example
(Hexa)
ID
Sign
Weight data
Decision
1 2 3 4 5
6 7 8 9 10
11 12 13
02
30
31
2B
31
32
33
2E
34
35
36
4C
03
02 30 31 2B 31
32 33 2E 34 35 36
4F
03
02 30 31 2B 31
32 33 2E 34 35 36
48
03
02 30 31 2B 31
32 33 34 35 36 2E
48
03
Output is conducted same as flickering of LED.
L
: RY1(LO) relay operation
O
: RY2(OK) relay operation
H
: RY3(HI) relay operation
A
: RY1(LO), RY2(OK) relay operation
B
: RY2(OK), RY3(HI) relay operation
C
: RY1(LO), RY3(HI) relay operation
F
: RY1(LO), RY2(OK), RY3(HI) relay operation
N
: RY1(LO), RY2(OK), RY3(HI) relay OFF or None of relay mode